6.6.7 Device Description file for EtherCAT
The Device Description file contains the specific configuration data of the device. The data must be
known to the controller. The manufacturers of the controller supply the tools for the integration of
the Device Description file into the network. Roland Electronic does not supply such tools, because
they have to be compatible with the interface design of the controller.
The Device Description file is supplied on a CD or can be downloaded from the Roland homepage.
Note
24 Bytes I/O must be set.
By pressing the key “
▼
” status indicators are shown on the display.
Status Indicators
Nr.
LED
State
Description
LED 1 Link/Activity 1
Off
No link sensed on Ethernet port 1
Green
Link sensed on Ethernet port 1
Green flickering Exchanging packets on Ethernet port 1
LED 2 RUN
Off
The device is in INIT state
Green, blinking
The device is in PRE-OPERATIONAL state
Green, single
flash
The device is in SAFE-OPERATIONAL state
Green
The device is in OPERATIONAL state
LED 3 ERR
Off
EtherCAT is in communication condition
Red, flashing
General configuration error
Red single flash Slave device application has changed the EtherCAT
state autonomously: Parameter „Change“ in the AL
status register is set to 01 (change/error).
Red double
flash
Sync manager watchdog timeout
Red
Application watchdog timeout
LED 4 Link/Activity 2
Off
No link sensed on Ethernet port 2
Green
Link sensed on Ethernet port 2
Green, flashing
Exchanging packets on Ethernet port 2