AEP-CHS-20191117 43
the print is optimized
2.8
If any change in bed temperature and Size of output, the Thermal Offset setting may
require adjustments.
[When the extruder has been replaced]
1.
Connect to the device by clicking the Connect button in NewCreatorK.
2.
Raise the temperature of the extruder to a temperature suitable for the filament material
and clean the nozzle surface.
3.
After setting the nozzle temperature to room temperature, wait until the temperature is
below 50
°
C.
4.
Run [Set Measure Probe] in the control window of NewCreatorK to prepare for using the
Autoleveling function. See section “Measure Probe Settings”.
5.
In the Basic window of NewCreatorK, execute [PID Tuning] so that the nozzle temperature
is kept at the set temperature stably. See section [PID Tuning].
[Measure Probe Settings]
1.
In NewCreatorK, click the [Connect] button to connect the device.
2.
Close the top lid of the equipment.
3.
In the [Connect] -> Control window, click "Set Measure Probe".
4.
Wait until the bed temperature reaches 50°C
5.
Once the extruder has reached the bed’s center, select the minimum Z-axis distance unit
between 0.1mm, 1mm, and 10mm.
6.
Click the Z-axis movement arrow until the nozzle touches the bed
7.
Once the nozzle has touched the bed, click "Set Probe Z Offset".
[PID Tuning]
3.
In NewCreatorK, click the [Connect] button to connect the device.
4.
At the bottom of the Basic window, enter the nozzle temperature of the material used in
the text box located to the right of [Show Cmd].
5.
Click the [PID Tuning] button.
6.
Repeat PID Tuning by repeatedly raising and lowering the nozzle temperature.
7.
When PID Tuning is completed, the message that “Tuning is completed “is displayed
[Product Quality]
1.
Measure Probe and PID tuning must be performed when the extruder is replaced or the
glass plate of the bed is remounted.