AEP-CHS-20191117 33
as follows:
1.
Set the correction value so that the “A + D = B + C” condition is met.
2.
To extend the spacing at point A 0.01 mm, add 0.005 to the existing value at point A
and subtract 0.005 to the existing value at point D
3.
To narrow the spacing at point C by 0.02 mm, subtract 0.01 from the existing value at
point C and add 0.01 to the existing value at point D.
Existing
A 0.1
B -0.1
→
Revised
A 0.105
B -0.09
C 0.1
D -0.1
C 0.09
D -0.105
Example 2) Given the setting value of nozzle and bed spacing as follows, to open the spacing
by 0.04mm at Point A and by 0.01 mm at point C, set the correction value as follows:
1.
Set the correction value so that the “A + D = B + C” condition is met.
2.
To extend the spacing at point A 0.04 mm, add 0.02 to the existing value at point A and
subtract 0.02 from the existing value at point D
3.
Add 0.005 to the existing value at point C and subtract 0.005 from the existing value at
point D to open the spacing at point C by 0.01 mm.
Existing
A 0.105
B -0.09
→
Revised
A 0.125
B -0.095
C 0.09
D -0.105
C 0.095
D -0.125
IMPORTANT!! In case of [RESET], '10.2 Pre-Autoleveling 'and '10.3 Thermal Expansion Bed
Calibration' should be executed in a proper order.
10.4 Filament Loading
1.
Place a filament bobbin in the filament holder
2.
Push the filament string through Guide Tube-A and until it reaches the Bowden block.
3.
Go to the printer’s LCD screen, click [Filament] > [Extruder1] > [2mm] followed by [LOAD].
4.
Check that the filament moves and is pulled up the tube at the click of LOAD. Once you