![Rohde ST 630 Скачать руководство пользователя страница 71](http://html1.mh-extra.com/html/rohde/st-630/st-630_operation-manual_1477610071.webp)
69 / 341 - EN -
6.5.5.
Programming the “END” ramp rate
To end a firing program, “END” must be programmed in the last segment.
Display
Meaning
Description
Remark
Pr. 1
Program
number
Select the firing program that is to
be changed.
See Section 6.5.1.
Indicator in the
segment
display
Select the segment with the
heating ramp to be changed into
a cooling ramp.
See Section 6.5.1.
150°C/HR
Heating ramp
Cooling ramp
The ramp rate for the heating or
cooling ramp is shown in the
main display.
Possible main display:
„0,1 °C/h-9,9 °C/h“,
„10 °C/h-999 °C/h“
END
Heating ramp
Cooling ramp
To mark the end of the program,
push the
f
key until "END"
appears in the main display.
•
“END” ends the firing program.
•
The firing program ends with the
segment in which “END” has been
programmed.
•
After “END” has been
programmed, the soak/target
temperature or soak time can no
longer be selected.
•
The “END” value is one step below
the ramp rate “0,1 °C/h”.
Note: If “END” is not entered in the
last segment, the controller issues the
error message “Error P” when the
program starts.
*The keys
h
or
g
can also be held down for faster input.
7.
Programming the additional switch output (ST 632 only)
7.1.
General description (ST 632 only)
The ST 632 control unit has 2 additional switch outputs that can be configured and activated in a firing program.
⇒
The switch output on the controller can control an automatic exhaust air flap or an automatic cooling system
using a fan on the kiln.
⇒
Each of the switching contacts outputs a voltage of 230 V AC and can be loaded with a maximum current of
500 mA.