65 / 341 - EN -
6.5.
Programming the control unit
6.5.1.
Changing the firing program
Indicator
on the
left
Main display
Heating
zone display
on the right
Meaning
Description
20 °C
No program
in operation
•
If no firing is carried out, no element lights
up in the program sequence of the
graphical display.
•
The “Program running” indicator must not
light up
•
The main display shows the current firing
chamber temperature of the respective
heating zone.
PROG: 1
Program number
selection
•
When you press the
g
key, the program
number lights up on the display.
•
The firing program can now be selected
with the
d
and
f
keys.
•
By pressing the
g
key again, the program
number which is to be changed can be
selected.
•
You can switch back to the previous value
in each step by pressing the
h
key.
Indicator in the
segment display
The selected firing program always shows the
first segment first.
150°C/HR
Heating ramp
Cooling ramp
•
The ramp rate in the main display appears
as:
⇒
“0,1°C/h-9,9°C/h” or
⇒
“10°C/h-999°C/h“ or
⇒
“FULL” or
⇒
“END”
•
This can be altered with the
d
&
f
keys.
•
The graphical display indicates whether a
heating ramp or a cooling ramp is being
programmed.
Notes:
⇒
To change the heating ramp to a cooling
ramp and vice versa, see Section
6.5.2./6.5.3.
⇒
To program the ramp rate to “FULL” or
“END”, see Section 6.5.4./6.5.5.
632°C
Soak/Target
temperature
•
The next press of the
g
key displays the
soak or target temperature.
•
This can be altered with the
d
&
f
keys.
00 : 15
Soak time
•
The next push of the
g
key displays the
soak period in “hours:minutes”.
•
This can be altered in the range 00:00 to
99:59 with the
d
and
f
keys.
•
The soak period indicator on the graphical
display will flash.
Содержание ST 630
Страница 344: ...20220531 01 ...