R&S FSH
Spectrum Analyzer Mode
Performing Spectrum Measurements
Operating Manual 1309.6275.12 - 14
66
If the R&S FSH is unable to find any AM modulated a carriers, it shows the message
.
Screen layout for the AM modulation depth measurement
1
Marker list
2
Modulation depth
3
Trace
4
Threshold line
5
Markers (blue lines)
6
AM modulation depth softkey menu
2.1.7.1 Setting a Threshold
You can set a threshold that defines the minimum power level the signal must have. If
the power of the signal is below the threshold, the R&S FSH will not set the markers
and therefore will not calculate the modulation depth.
M
Press the MEAS key.
M
Press the "Threshold" softkey
The R&S FSH opens an input field to set the threshold.
M
Enter the threshold value you need.
The threshold is represented as a horizontal blue line in the diagram area.
2.1.7.2 Optimizing the Settings
In order to get the best results, you can use the automatic adjustment routine that the
R&S FSH offers.
M
Press the MEAS key.
M
Press the "Adjust Settings" softkey.
The R&S FSH performs a sweep and repeats the peak search sequence for the
three markers.
Содержание FSH4
Страница 1: ...R S FSH4 8 Spectrum Analyzer Operating Manual 1309 6275 12 14 Test Measurement Operating Manual ...
Страница 19: ......
Страница 245: ......