![Rohde & Schwarz FSH4 Скачать руководство пользователя страница 197](http://html.mh-extra.com/html/rohde-and-schwarz/fsh4/fsh4_operating-manual_1477834197.webp)
R&S FSH
Digital Modulation Analyzer
Measurements on 3GPP FDD Signals
Operating Manual 1309.6275.12 - 14
178
P-CPICH Slot
Shows the slot number the results are displayed for.
Ch(annel) Search
Shows the status of the channel search.
7.2.1.2 Global Results
Global results contain various measurement results of the composite signal. These
results evaluate the total signal over the period of one slot.
Channel Power
Shows the power of the complete signal in dBm.
Carrier Frequency Error
Shows the frequency error in relation to the current center frequency of the R&S FSH.
The absolute frequency error is the sum of the frequency error of the R&S FSH and
that of the device under test. If the frequency error is more than 1 kHz, the R&S FSH is
not able to synchronize with the signal. If possible, you should synchronize the receiver
and the transmitter.
I/Q Offset
Shows the DC offset of the signal in %.
This value is valid only after performing a channel search.
I/Q Imbalance
Shows the I/Q Imbalance of the signal in %.
This value is valid only after performing a channel search.
Composite EVM
Shows the Error Vector Magnitude in %.
The EVM is defined as the ratio of the mean error power of the signal to the power of
an ideal reference signal. To calculate the mean error power, the root mean square
average (of the real and imaginary parts of the signal) is used.
This value is valid only after performing a channel search.
Active Channels
Shows the number of active channels in the signal.
Scr Code Found
Shows the number of the primary and secondary scrambling code, regardless if it has
been found automatically or entered manually.