![Rohde & Schwarz FSH4 Скачать руководство пользователя страница 159](http://html.mh-extra.com/html/rohde-and-schwarz/fsh4/fsh4_operating-manual_1477834159.webp)
R&S FSH
Network Analyzer Mode
Evaluating the Results
Operating Manual 1309.6275.12 - 14
140
M
Press the "Zoom Active" softkey.
The R&S FSH now zooms in on
the area covered by the zoom
window. You can position the
zoom window more accurately
with the "Move X" and "Move Y"
softkeys as described.
M
To deactivate the zoom
functionality, press the "Zoom
Active" softkey again.
Using markers
In addition to the standard marker functionality, the Smith chart also features several
marker output formats.
C
dB Mag Phase
Shows the magnitude (in dB) and the phase at the current marker position.
C
Lin Mag Phase (Rho)
Shows the converted magnitude (in %) and the phase (in rho) at the current
marker position.
C
Real + Imag (Rho)
Shows the real and imaginary components at the current marker position.
C
R + jX
Shows the real and imaginary components of the impedance at the marker
position. The imaginary component is converted to inductance or capacitance.
Marker frequency and sign are taken into account.
C
G + jB
Shows the real and imaginary components of the admittance at the marker
position. The imaginary component is converted to inductance or capacintance.
Marker frequency and sign are taken into account.
C
(R + jX/Z0)
Shows the real and imaginary components of the standardized impedance.
C
(G + jB/Z0)
Shows the real and imaginary components of the standardized admittance.
M
Press the MARKER key.
The R&S FSH activates a marker and opens the marker softkey menu. Like usual
traces, you can move the marker around with the rotary knob or the cursor keys, or
enter a specific marker position.