7.4.4.3 Synchronizing to a Base Station Using a GPS Receiver
If you use a GPS receiver while performing measurements on a base station, you can
synchronize the sweep via the GPS receiver.
M
Press the SWEEP key.
M
Press the "Trigger" softkey.
M
Select GPS Sync menu item.
The R&S FSH now synchronizes the sweep to the signal using the GPS receiver.
7.5 Measurements on LTE Signals
Equipped with the software application R&S FSH-K50 and R&S FSH-K51, you can
perform measurements on downlink LTE FDD (R&S FSH-K50) and TDD (R&S FSH-
K51) signals in accordance to the 3GPP standard with your R&S FSH.
Bandwidth of LTE signals
Because of the bandwidth of LTE signals, measurements are possible only with
instruments that support a bandwidth of 20 MHz (serial numbers 105000 and higher).
M
Press the MODE key
M
Press the "Dig Mod Analyzer" softkey.
M
Select the "LTE-FDD BTS" menu item for FDD measurements.
M
Select the "TD-LTE BTS" menu item for TDD measurements.
The R&S FSH starts the signal analysis.
To get highest measurement accuracy, it is necessary to synchronize the reference
frequency of the R&S FSH with the base station via the EXT REF IN input.