Operating Manual 1309.6275.12 - 14
137
VSWR
Shows the (voltage) standing wave ratio of the DUT.
The VSWR is the ratio of the maximum to the minimum voltage that occur in an
electrical transmission line. It is a measure of the reflected power at the input of the
DUT. The results are displayed in a Cartesian diagram with a logarithmic vertical axis.
Available for vector reflection measurements.
Reflection coefficient
Shows the reflection coefficient of the DUT.
The reflection coefficient is the ratio of the amplitude of a reflected wave and that of the
incidental wave that occur in an electrical transmission line.
You can set the unit for the reflection coefficient.
M
Press the AMPT key.
M
Press the "Unit" softkey.
Available for vector reflection measurements.
Smith chart
Shows the measurement results in the Smith chart.
The Smith chart is a circular diagram that primarily shows impedance or reflection
characteristics of a DUT.
Available for vector reflection measurements.
For more information see "
Cable loss
Shows the cable loss characteristics of a DUT.
The cable loss is a measure to determine the attenuation of a cable in a particular
frequency range. The diagram is a Cartesian diagram with a logarithmic vertical axis
that shows the cable attenuation. The horizontal axis represents the measured
frequency range.
Available for vector reflection measurements.
Group delay
Shows the group delay characteristics of the DUT.
The group delay is a measure that describes the time period or delay of the signal as it
goes through the DUT.
Available for vector measurements.