R&S FSH
Digital Modulation Analyzer
Measurements on LTE Signals
Operating Manual 1309.6275.12 - 14
210
7.5.4.4 Selecting the Subframe Configuration for TDD Signals
According to the standard, the R&S FSH provides 7 configurations that each covers a
complete LTE frame and consists of 10 subframes.
M
Press the MEAS key.
M
Press the "Signal Settings" softkey.
M
Select the "UL/DL Configuration" menu item.
The R&S FSH opens a submenu that contains the configurations.
M
Select the TDD configuration you need.
Each configuration is made up out of 10 of the following abbreviations:
C
"D" stands for a downlink subframe
C
"U" stands for a uplink subframe
C
"S" stands for a special subframe
A configuration for a frame therefore would be, e.g. "DSUUU DSUUU".
Note that this is available with option R&S FSH-K51 (TDD measurements) only.
7.5.4.5 Selecting the Synchronization Signal
The synchronization signal selects the way the R&S FSH synchronizes to the LTE
signal. By default, the R&S FSH automatically determines the type of synchronization
signal to use.
Alternatively, you can select the synchroniztaion signal manually. You can either
synchronize to the PSYNC or SSYNC signals or synchronize to the reference signal.
M
Press the "Signal Settings" softkey.
M
Select the PSYNC/SSYNC menu item.
The R&S FSH synchronizes to the PSYNC or SSYNC.
M
Select the "Reference Signal" menu item.
The R&S FSH synchronizes to the reference signal. For more information see
"
7.5.4.6 Selecting the MIMO Configuration
You can perform measurements on equipment with 1, 2 or 4 transmission antennas.
For measurements on base stations with one or two transmit antennas it is possible to
perform detailed measurements on single antennas via cable connection.
Because the reference signals of the different antennas are orthogonal, it is possible to
determine and display their power and EVM during over-the-air measurements.
M
Press the MEAS key.
M
Press the "Antenna Settings" softkey.