5.1.3 Spectrum Measurements
The spectrum measurement provides an overview of the spectrum of the DUT without
the necessity to change the operating mode. This measurement is well suited for a
quick check if there are any interfering signals that may impair results before you start
the actual measurement.
M
Press the "Meas Mode" softkey.
M
Select the "Spectrum" menu item.
The R&S FSH shows the current spectrum.
5.1.4 Selecting the Measurement Format
You can select several measurement formats for each measurement. The
measurement format selects the way the results are displayed.
C
Magnitude (dB Mag)
This is the default format. It shows the magnitude of the results in dB.
C
V
SWR
The VSWR shows the standing wave ratio in a cartesian diagram. The VSWR is
the ratio of the maximum voltage and the minimum voltage that occur in an
electrical transmission line. The VSWR format is available for DTF and reflection
measurements.
C
Reflection Coeffcient
Shows the reflection coefficient of the DUT.
The reflection coefficient is the ratio of the amplitude of a reflected wave and that
of the incidental wave that occur in an electrical transmission line.
C
Cable Loss
The cable loss measurement evaluates the power attenuation of a cable over a
specified frequency range in dB. The amount of power that gets absorbed depends
on the frequency and the length of the cable.
The cable loss format is available for reflection measurements.
The following pictures show the results of a reflection measurement in Magnitude
format (left side) and VSWR format (right side).