ID_CODE
<ID>
This command queries the ID of the signal in "NDB" mode.
Parameters:
<ID>
three or four characters
Manual operation:
See
NDB_IDFREQ_400_1020
<Freq>
This command gets or sets the frequency of the ID in "NDB" mode.
Parameters:
<Freq>
400HZ | 1020HZ
Manual operation:
See
NDB_K2_PCT
This command queries the K2 distortion parameter of an NDB signal.
Return values:
<[%]>
K2 distortion value of an NDB signal
Manual operation:
See
NDB_K3_PCT
This command queries the K3 distortion parameter of an NDB signal.
Return values:
<[%]>
K3 distortion value of an NDB signal
Manual operation:
See
NDB_K4_PCT
This command queries the K4 distortion parameter of an NDB signal.
Return values:
<[%]>
K4 distortion value of an NDB signal
Manual operation:
See
NDB_POWSUPPL_FC
Queries the distortion of the power supply frequency component in "NDB" mode.
Parameters:
<Power>
Distortion caused by the power supply frequency component
Default unit: percent
NDB Mode