Numeric Measurement Modes
R&S
®
EVSG1000
124
User Manual 1178.6227.02 ─ 06
Status flags
The "STIOCPMV" value contains status flags, if applicable:
●
S
: Start (started manually)
●
T
: Triggered (externally)
●
I
: Invalid
●
O
: Overload (RF input signal too high)
●
C
: Corrected (includes RF input correction factor)
●
P
: PPS-synced
●
M
: Morse ID available
●
V
: Valid signal (ILS LOC/GP and VOR only)
4.4.2
COM Configuration
In this view, the measurements settings available for the currently active mode, can be
configured.
Channel and Frequency Configuration
................................................................. 124
Setting the Measurement Time (MTime)
...............................................................127
4.4.2.1
Channel and Frequency Configuration
The ILS Localizer and Glidepath measurements can detect both course and clearance
carriers simultaneously. Alternatively, the individual carriers can be measured only, or
any one or two user-defined frequencies. By default, a wideband measurement is per-
formed. The available measurement settings depend on the selected channel and fre-
quency configuration.
.............................................................................................125
Channel Frequency Configuration (CH FREQ)
.....................................................125
Channel Setup
Access
: > [Meas] > "1F/2F"
Access VNC
: [a] > [F1]
1F/2F
Selects the number of frequencies or channels to be measured.
"1F"
One frequency only is measured, namely the nominal frequency,
which is also the center frequency.
The nominal frequency is configured by the
COM Mode (Option R&S
EVSG-K6)