Remote Control/Annex C
CTS60
1094.0006.60 C.36
E-5
Identification Query
Syntax:
*IDN?
Return:
ROHDE&SCHWARZ, CTSzz, .ssssss/sss, xx.xx yy.yy.yy
(zz is the model no., eg 55, 60 or 65
ssssss/sss is the serial number of the testset, eg 123456/789
xx.xx is the software version, eg V 1.00
yy.yy.yy is the date, eg 18.10.93)
State:
ALL
Option:
none Query only
Individual Status Query
Syntax:
*IST?
Return:
0 | 1
State:
ALL
Option:
none Query only
Operation Complete
Syntax:
*OPC
Return:
1
(return only in the case of query)
State:
ALL
Option:
none With Query
Note:
Also influences the OPC bit in the event status register
Parallel Poll Enable Register Enable
Syntax:
*PRE <numeric_value>
Value range:
0 ... 255
Default:
0
State:
ALL
Option:
none With Query
Note:
MAXimum and MINimum impermissible
Power-on Status Clear
Syntax:
*PSC <numeric_value>
Value range:
-32767 ... 32767
Default:
1
State:
ALL
Option:
none With Query
Note:
MAXimum and MINimum impermissible
Reset
Syntax:
*RST
Status:
ALL
Option:
none No query
Note:
Sets the instrument to the default status (without considering an
established call); however, it does not affect the remote-control
settings