CTS60
Autotest Printed Reports
1094.0006.60
7.7
E-3
7.3.3 Power
Ramp
____________________________________________________________________
| (02) Power Ramp (Bursts = 4): |
| Value Limits Result |
| Min. Max. |
| NTP (dBm) 22.0 20.0 25.0 OK |
| B (abs) (uW) PASS 25 OK |
| C (rel) (dB) PASS 4.0 OK |
| D (rel) (dB) PASS 1.0 OK |
| E (rel) (dB) PASS -1.0 OK |
| F (rel) (dB) PASS -6.0 OK |
|____________________________________________________________________|
This section of the report displays the results of the power ramp measurement. The first line details the
test step number in brackets, and the title "Power Ramp" to show that this is a power ramp
measurement. After this, in brackets, is the number of bursts configured for this measurement.
Below this is a table of the configured values and measured results for the measurements. The first
column details what was measured and its unit in brackets. Under "Value" is listed all of the measured
values for this measurement. The column "Limits" has been split into two columns "Min." and "Max.".
This display the minimum and maximum configured tolerance limits for each of the measurements. The
final column "Result" gives a result as to whether the measurement has passed the tolerance check.
NTP
This line details the Normal Transmit Power value measured for this test step in dBm.
Template levels (B-F)
These measurements detail whether each of these sections of the power ramp have passed or failed
the tolerance check indicated by "PASS" or "FAIL" in the "Value" column.