Remote Control/Annex C
CTS60
1094.0006.60 C.26
E-5
15.
Menu: Timing Configuration
Number of bursts for timing measurement
Syntax:
CONFigure:TIMing:AVERage:BURSt <numeric_value>
Value range:
2 .. 1000
Default:
32
State:
ALL
Option:
none With query
Reset to Default Value
Syntax:
CALCulate:LIMit:TIMing:CLEar
State:
ALL
Option:
none No query
Tolerance Range for Time Accuracy
Syntax:
CALCulate:LIMit:TIME:ACCuracy:TOLerance[:DATA] <numeric_value>
Value range:
0.0 ... 100.0 ppm
Default:
5.0 ppm
State:
ALL
Option:
none With query
Note:
The tolerance range is symmetrical
Tolerance Range for Jitter
Syntax:
CALCulate:LIMit:JITTer:TOLerance[:DATA] <numeric_value>, <numeric_value>
Value range:
-100.0 ... 0.0 µs
0.0 ... 100.0 µs
Default:
Minimum: -1.0
µs
Maximum: 1.0 µs
State:
ALL
Option:
none With query
Note:
The first value is minimum, the second one is maximum tolerance
Tolerance Range for Packet Transmission Accuracy
Syntax:
CALCulate:LIMit:PACKet:DELay:TOLerance[:DATA] <numeric_value>, <numeric_value>
Value range:
-10.0 ... +10.0 µs
Tolerance for minimum
-10.0 ... +10.0 µs
Tolerance for maximum
Default:
-2.0
µs
+2.0 µs
State:
ALL
Option:
none With query
Note:
The tolerance range is symmetrical