66
-
Bypassed zones by the users using [*][3][User Code] or [BYPASS][User Code] commands.
2.
If one event code should keep its value previously set, press [#] key instead of that corresponding digit.
3.
If one event code isn’t to be reported to CS, the digit which corresponds to the event will be set as [0] value.
4.
Each digit specific to “zone bypassed from swinger” and “zone bypassing” events will be used by the panel to generate the
event codes for 4x2 transmissions to the “central station” (4 account 2 event digits). So, for the zone that
generated events of the type: “zone bypassing” or “zone bypassed from swinger”,
in order to get the 2 event digits, the
panel will automatic add to these specific digits the corresponding digit of the zone number (1 to 6).
S
ECTION
[56]
-
E
VENT
R
EPORTING
C
ODES IN
4
X
2
F
ORMAT REGARDING
:
“R
OUNDS STARTED
”
/
“R
OUNDS
FINISHED
”
/
“
ROUND
OK”
/
“R
OUND
F
AILED
”
/
“A
MBUSH ON
R
OUND
”
Enter 5 groups of 2 digits (HEX digits may be used), one group for each reporting event.
The following sequence will be introduced:
|__|__||__|__||__|__||__|__||__|__| |00||00||00||00||00|
by
default
The keypad buzzer will sound 3 beeps after each 2-digit group and 6 beeps after the last digit. Then
the panel exits the section and will wait for a new command to enter another section.
To exit the “main programming menu”, press [#] key.
Notes:
1.
If one event code should keep its value previously set, press [#] key instead of the corresponding group.
2.
If one event code isn’t to be reported to CS, the 2 digits which correspond to the event will be set as [00] value.
3.
In case of any 4x2 formats were set by programming, the panel will report to CS as follows:
-
for the “starting/finishing the rounds” by users using [*][9][user code][6 key] command, the control panel will
transmit to CS the same specific reporting codes regarding “rounds started” and “rounds finished”, established in this
section, indifferently of user number (users cannot be identified to CS in 4x2 formats, when they are “starting/finishing
the rounds” by means of [*][9][user code][6 key] command).
-
for “round OK”, “round failed” and “ambush on round” events, the panel will report to CS the same specific reporting
codes established in this section, indifferently of zone number (zones cannot be identified to CS in 4x2 formats in case
of these events).
S
ECTION
[57]
–
E
VENT
R
EPORTING
C
ODES IN
4
X
2
F
ORMAT REGARDING
:
“B
URGLARY
A
LARM
”
/
“T
AMPER
A
LARM
”
/
“P
ANIC
A
LARM
”
/
“F
IRE
A
LARM
”
/
“M
EDICAL
E
MERGENCY
A
LARM
”
/
“U
SER
U
NDER
D
URESS
(
AMBUSH
)
”
Enter 6 digits (HEX digits may be used), one digit for each event.
The following sequence will be introduced:
|__|__|__|__|__|__|
|3|0|2|1|4|0| by default
The keypad buzzer will sound 3 beeps after each digit and 6 beeps after the last one. Then the panel
exits the section and will wait for a new command to enter another section.
To exit the “main programming menu”, press [#] key.
Notes:
1.
If one event code should keep its value previously set, press [#] key instead of that corresponding digit.
2.
If one event code isn’t to be reported to CS, the digit which corresponds to the event will be set as [0] value.
3.
Each digit specific to each event will be used by the panel to generate the event code for transmission to the “central
station” in 4x2 formats (4 account 2 event digits).
So, in order to get the 2 event digits, to these specific
event digits, the panel will automatic add:
-
The corresponding digit of the user number
(for all users from 15 to 45 the identifying digit of user number will be
either “F” or modulo 16, according to the corresponding flag programming from section [29]), in case of “user under
duress” event;
-
The corresponding digit of the zone number
(1 to 6) for the zone that generated events, of the type: “burglary
alarm”/”tamper alarm”/”panic alarm”/”fire alarm”/”medical emergency alarm”;
-
The digit [0] for triggered from keypad events
of the type: “panic alarm”/”fire alarm”/”medical emergency alarm”
(triggered events by simultaneously pressing the corresponding key combinations).
S
ECTION
[58]
–
E
VENT
R
EPORTING
C
ODES IN
4
X
2
F
ORMAT REGARDING
:
“K
EYPAD
L
OCKOUT
”/”Z
ONE
RESTORE
”
Enter 2 groups, first of 2 digits and second of 1 digit (HEX digits may be used), one group for each
reporting event.
The following sequence will be introduced:
|__|__||__|
|50||E|
by
default