33
The command will be accepted only if the system is disarmed.
Notes:
1.
This command is the same as the one described within programming section [99], which is dedicated to the installer, with the
exception that
the “master user” can only stop
the voice/sound reporting and the communication between panel and PC,
without stopping the digital communication between control panel and central station.
2.
When any alarm occurs, just entering a user code (the “master code” included) will only disarm the system/partition and/or
stop the siren sound, without cancellation of the voice message/sound dialing.
3.
In order to stop the voice message/sound dialing
, in case an alarm was triggered and the voice/sound dialer has
already started the reporting of the voice messages to the follow me phone numbers,
first
users should disarm the
system/partition and/or stop the siren sound
by any valid user code,
then the master user should enter
[*
][
8
][
Master Code
][
99
][
#] command.
Please note that the cancellation of the voice/sound reporting
is allowed only to
the master user, not to the users from 2 to 45.
K
EYPAD
S
PECIAL ALARMS
Depending on the installer programming, Cerber C62 will send a reporting code to the “central
station” (and/or a phone voice message), according to the occurrence of one of the next events: Panic,
Fire, Medical Emergency and Maintenance Request.
These events occur
by activating the correspondingly 24h defined zones, or
by simultaneously
pressing a combination of keys from keypad:
[1] + [3]
Medical Emergency alarm
[7] + [9]
Fire alarm
[4] + [6]
Maintenance Request
[*] + [#]
Panic alarm
In order to stop any alarm status, enter [#] key followed by any 4
or
6-digit user code from
1 to 45.
Note:
The “keypad panic” alarm ([*] + [#]) should be used in emergency situations, when the user is threatened and the possible
offender must not be notified about sending the respective message. In this case, the “keypad panic” alarm should be set of the
silence type (you should see section [21] – System OPTIONS
2
, zone 6 LED).
6. Programming of the System Parameters
(“main programming menu”)
In order to enter the programming menu of system parameters (“
main programming
menu
”), the installer should use the command [*
][
8
][
Installer’s programming code], while
the system is partially armed.
Notes:
1.
The default value of the installer’s programming code is “0269” and it should be changed before or after the
system parameters were programmed.
2.
All programming sections are dedicated to the installer and only some of them are accessible to the master user, too.
3.
If the digital communicator will be enabled by programming and the corresponding reporting codes will be programmed, too,
then
any accessing of “
main programming menu
” by the installer (or by the master user) will be transmitted to
CS, as follows:
-
In case of any 4x2 formats will be set by programming, the control panel will transmit to CS the same specific
reporting codes regarding “programming entry” / “programming exit” / “panel programming changed” events, which
will be set in [61] and [62] sections, even the respective operations will be performed by the installer or by the master
user (whether these operations are performed by the installer or by the master user, there will be no difference
between them in 4x2 formats).
-
In case of CID format will be set by programming, the control panel will transmit to CS the specific reporting codes
regarding “programming entry” / “programming exit” / “panel programming changed”, which will be set in [72] and
[73] sections; after the 4-digit group specific to these reporting events the panel will transmit to CS another 3-digit
group which stands for the master user or for the installer identifying. In CID format the installer will be identified as
user “000” and the master user as user “001”.
System programming parameters are explained bellow.
To enter the programming menu of system parameters (“
main programming menu
”), follow
the next steps:
1. Enter the command: [*
][
8
][
Installer’s programming code];