3.
A
FTER ENTERING THE LAST DIGIT OF THE
“
MAINTENANCE CODE
”
the keypad buzzer will sound 3
confirmation beeps and the panel will pass to the next step, displaying
ON ZONE
1
TO
5
LED
S THE
RIGHTS
1
SET
of the just modified “maintenance code”, as follows:
While the control panel is being within “maintenance code” RIGHTS
1
displaying session, the keypad
LEDs’ status will be as follows:
ARMED A LED
ON
SYSTEM LED
Blinking
READY LED
ON
1 to 5 zone LEDs
ON/OFF
, according to the
RIGHTS
1
set of the just modified “maintenance code”
By
[#] key pressing, RIGHTS
1
set
of the “maintenance code” can be maintained
as it was
previously established.
3.1 The rights of the “maintenance code” are display-able on zone 1 to 5 LEDs; in order to
turn the rights activate/deactivate, the installer should press the 1 to 5 keys and the
appropriate zone LED will turn ON/OFF.
If the a zone LED is ON that means the appropriate right
is enabled and if the zone LED is OFF that means the right is disabled.
RIGHTS
1
set for “maintenance code”:
zone LEDs
ON
OFF
zone 1 LED
enabled
disabled
Zone bypassing
zone 2 LED
enabled
disabled
Regular arming
zone 3 LED
enabled
disabled
Stay arming
zone 4 LED
enabled
disabled
Force arming
zone 5 LED
enabled
disabled
Disarming/siren stopping;
zone 6 LED
reserved reserved -
Note:
Installer can disarm the system/partition using the “maintenance code” only if previously the same “installer’s maintenance
code” armed the system.
3.2 Finally installer should press [#] key to confirm the RIGHTS
1
set
of the “maintenance
code”.
4.
A
FTER
[#]
KEY PRESSING
THE KEYPAD BUZZER WILL SOUND
3
CONFIRMATION BEEPS AND THE PANEL WILL PASS TO THE
NEXT STEP
,
DISPLAYING
ON
1
TO
6
ZONE
LED
S THE
RIGHTS
2
SET
of the modifying “maintenance code”, as
follows:
While the control panel is being within “maintenance code” RIGHTS
2
displaying session,
the keypad LEDs’ status will be as follows:
ARMED A LED
ON
SYSTEM LED
Blinking
READY LED
ON
1 to 6 zone LEDs
ON/OFF
, according to the
RIGHTS
2
set of the modifying “maintenance
code”
By
[#] key pressing, RIGHTS
2
set
of the “maintenance code” can be maintained
as it was
previously established.
4.1 The user code rights are display-able on 1 to 6 zone LEDs; in order to turn the rights
activate/deactivate, the installer should press the 1 to 6 keys and the appropriate zone LED
will turn ON/OFF.
If the a zone LED is ON that means the appropriate right is enabled and if the zone
LED is OFF that means the right is disabled.
RIGHTS
2
set for “maintenance code”:
zone LEDs
ON
OFF
zone 1 LED
enabled
disabled
PGM1 activating/deactivating