4. In order to manually start/finish the rounds,
the user should
press [6] key
and the
zone 6 LED will turn ON/OFF
.
If the zone 6 LED is ON means the “rounds” are being into progress
and, if the zone LED is OFF means the “rounds” were finished.
Any successful command of
starting/finishing the rounds is followed by an automatic exit from menu after about 1 second, like
after [#] key pressing after 1 sec.
Notes:
a)
In case one user is trying to activate/deactivate the PGM outputs (or is trying to start/finish the rounds) and the respective
user code hasn’t the right enabled, then the keypad buzzer will sound a long error beep and will reject the respective
command.
b)
The keypad buzzer will sound a long error beep and the panel will reject the command, too, if users try to
activate/deactivate any PGM output which was not set as retriggerable or resetable mono-stable, as bi-stable or as clock
timer, even if the respective user code has the right enabled by programming.
c)
If the digital communicator is enabled by programming and the appropriate reporting codes are programmed, too, then the
“starting/finishing the rounds” and “PGM activation/deactivation” by users will be transmitted to CS.
5.
If no successful command was performed, finally the user should press [#] key to
exit
from the visualization of the status of PGM1, PGM2 and rounds. The keypad buzzer will sound 6
confirmation beeps and the
system will go back within armed/disarmed status,
the keypad LEDs
being displaying the system and zone status.
5. Master User’s Programming Menus
While the system is partially armed,
in order to enter the main programming menu allowed only
to the “master user” enter one of the [*
][
7
][
Master Code]
or
[CODE
][
Master Code]
commands,
where [CODE] is the key labeled “CODE” key
Once this procedure was initialized by entering [*] or [CODE] key, all the keypad LEDs will turn OFF.
After entering the “master code”, the keypad buzzer will sound 3 beeps, confirming the
system is
being within “master user’s programming menu”.
While the system is being within
“master user’s programming menu”, the keypad LEDs’ status will be as
follows:
ARMED A LED
ON
SYSTEM LED
Blinking
READY LED
OFF
zone LEDs
OFF
Note: The “master user’s programming menu” can be exited by [#] key pressing.
When exiting the “master user’s
programming menu”, the system will go back within disarmed status and the keypad LEDs will display the system and zone status.
There are several “master user’s submenus” where the “master user” can perform the
following operations:
1.
Selective Programming/Erasure of 01 to 45 user codes
(“master user’s submenus” from
[01] to [45]);
2.
Simultaneous Erasure of all user codes
, except the “master code” (“master user’s submenu”
[49]);
3.
Selective Programming/Erasure of the follow me phone numbers
(“master user’s
submenus” from [51] to [54]);
4.
Simultaneous Erasure of all follow me phone numbers
(“master user’s submenu” [50]);
5.
Programming session of the system time and date
(“master user’s submenu” [60]).
6.
“Ambush Digit Programming”
(“master user’s submenu” [61]).
While the system is being within “master user’s programming menu”,
in order to program the 01 to
45 user codes, the follow me phone numbers, the system time and date or the “ambush