9
•
Fast Blinking – during any arming period, after any delayed zone which belongs to the
partition A or to the system triggered the alarm.
•
Slow Blinking – if the partition A or the system is armed in “stay mode”.
b) While the partition A or the system is disarmed:
•
OFF
•
ON – while the master user is being within menu of program/modify the user codes, follow
me phone numbers or system time and date;
•
ON - while the installer is being within programming menu of the system parameters.
ARMED B LED
a)
While the partition B is armed:
•
ON – if the partition B is totally armed;
•
Fast Blinking – if the partition B is armed in “instant stay mode”.
•
Fast Blinking – during any arming period, after any delayed zone which belongs to the
partition B triggered the alarm.
•
Slow Blinking – if the partition B is armed in “stay mode”.
b)
While the partition B is disarmed: OFF
Zone LEDs
a) While the system is completely armed:
•
ON – the corresponding zone triggered the alarm at least once during arming;
•
Blinking – if zone tamper condition occurred
•
If the corresponding zone triggered the alarm at least once and tamper condition had
occurred on the same zone, during armed state of the system, zone LEDs are ON for 2
seconds and blinking for the next 2 seconds, and so on
b) While the system is completely disarmed or partial armed:
•
OFF – the loop of corresponding zone is closed;
•
ON – the loop of corresponding zone is faulted.
•
While the system finds itself within one of the programming/displaying menus:
o
ON – the user is being within one the zone bypassing menu and the respective zone is
bypassed;
o
ON/OFF – they are displaying certain parameters’ status (activate/deactivate) – while
the installer is being within certain sections of programming menu of the system
parameters.
F
UNCTIONAL
K
EYS
Functional Keys: [*], [STAY], [BYPS], [INST], [CODE] and [<], [>]
(only for keypad KP-064EP)
– are functionally only while the system is partially armed
; if pressed while system is total
armed, the keypad buzzer will sound a long rejection beep.
[STAY]
It is used for system perimeter arming (“stay arming” or “instant stay arming”).
[BYPS] ([BYPASS])
It is used for zone bypassing;
[INST]
It is used for instant stay
arming or for system/partition arming without code (“INST”+ “CODE”).
[CODE]
It is used for system/partition arming without code or to program/modify the user codes, the
follow me phone numbers or the system time and date.
[<] & [>
] (only on KP-064EP)
They are used to display the first 9 alarms occurred in the system since last arming.