64
[0
][
2]
10PPS, 4x2 no parity, 1400Hz kisson, 1800Hz data
[0
][
3]
10PPS, 4x2 no parity, 2300Hz kisson, 1800Hz data
[0
][
4]
10PPS, 4x2 with parity, 1400Hz kisson, 1900Hz data
[0
][
5]
10PPS, 4x2 with parity, 2300Hz kisson, 1900Hz data
[0
][
6]
10PPS, 4x2 no parity, 1400Hz kisson, 1900Hz data
[0
][
7]
10PPS, 4x2 no parity, 2300Hz kisson, 1900Hz data
[2
][
0]
20PPS, 4x2 with parity, 1400Hz kisson, 1800Hz data
[2
][
1]
20PPS, 4x2 with parity, 2300Hz kisson, 1800Hz data
[2
][
2]
20PPS, 4x2 no parity, 1400Hz kisson, 1800Hz data
[2
][
3]
20PPS, 4x2 no parity, 2300Hz kisson, 1800Hz data
[2
][
4]
20PPS, 4x2 with parity, 1400Hz kisson, 1900Hz data
[2
][
5]
20PPS, 4x2 with parity, 2300Hz kisson, 1900Hz data
[2
][
6]
20PPS, 4x2 no parity, 1400Hz kisson, 1900Hz data
[2
][
7]
20PPS, 4x2 no parity, 2300Hz kisson, 1900Hz data
[4
][
0]
40PPS, 4x2 with parity, 1400Hz kisson, 1800Hz data
[4
][
1]
40PPS, 4x2 with parity, 2300Hz kisson, 1800Hz data
[4
][
2]
40PPS, 4x2 no parity, 1400Hz kisson, 1800Hz data
[4
][
3]
40PPS, 4x2 no parity, 2300Hz kisson, 1800Hz data
[4
][
4]
40PPS, 4x2 with parity, 1400Hz kisson, 1900Hz data
[4
][
5]
40PPS, 4x2 with parity, 2300Hz kisson, 1900Hz data
[4
][
6]
40PPS, 4x2 no parity, 1400Hz kisson, 1900Hz data
[4
][
7]
40PPS, 4x2 no parity, 2300Hz kisson, 1900Hz data
[1
][
0]
DTMF, 4x2 Ademco Express
[9
][
0]
DTMF, Ademco Contact ID
Notes:
1.
Switching format types between Contact ID and 4x2 formats is recommended to be performed without any active CS
transmission.
2.
Any time when the control panel is dialing the 1
-st
CS phone number, the panel will report in the 1
-st
reporting format which
is set in this section, irrespective of way the alternate or split reporting option was set.
3.
The panel will report in the 2
-nd
reporting format which is set in this section, only if the split (or double) reporting option
was set and only while the control panel is dialing the 2
-nd
CS phone number.
S
ECTION
[52]
–
E
VENT
R
EPORTING
C
ODES IN
4
X
2
F
ORMAT REGARDING
:
“A
RMING BY
U
SER
”
/
“K
EYSWITCH
A
RMING
”
/
“A
RMING FROM
PC”
/
“T
IMED
A
UTOARMING
”
/
“I
NACTIVITY
A
UTOARMING
”
/
“A
WAY
Q
UICK
A
RMING
”
Enter 1 digit for “arming by user” code and 5 groups of 2 digits (HEX digits may be used), one group
for each reporting event.
The following sequence will be introduced:
|__||__|__||__|__||__|__||__|__||__|__|
|C||00||00||00||00||00|by
default
The keypad buzzer will sound 3 beeps after each digit group and 6 beeps after the last digit. Then the
panel exits the section and will wait for a new command to enter another section.
To exit the “main programming menu”, press [#] key.
Notes:
¾
If one event code isn’t to be reported to CS, the group (digit) which corresponds to the event will be set as [00] value (or as
[0] value).
¾
If one event code should keep its value previously set, press [#] key instead of the corresponding group (digit).
¾
First digit specific for “arming by user” event will be used by the panel to generate the event code for transmission to the
“central station” in 4x2 formats (4 account 2 event digits).
So, in order to get the 2 event digits, the panel will
automatic add to this specific digit the corresponding digit of the user number
(for all users from 15 to 45 the
identifying digit of user number will be either “F” or modulo 16, according to the corresponding flag programming from section
[29]).