2-88 Parameter
Descriptions
7000-TD002A-EN-P – September 2007
Drive Fault Mask 3 [Drv Fault3 Mask]
Linear Number:
396
Default Value:
1111111111111111
Access Level:
Basic
Read/Write:
Read/Write
This parameter specifies the mask for the third fault word corresponding to drive protection. A ‘1’
represents an enabled fault; a ‘0’ represents a disabled fault. The bit assignment is:
Bit
Enum Text
Description
0
Drv OvrLoad
Drive Overload Fault
1
RNeutOvrLoad
Line Neutral to Ground Overvoltage Fault
2
RecHSnkOvTmp
Rectifier Heatsink Over Temperature Fault
3
RecHSnkLoTmp
Rectifier Heatsink Low Temperature Fault
4
RecHSnkFbrOp
Rectifier Heatsink Fiber Optic Cable Loss Fault
5
RecHSnk Sens
Rectifier Heatsink Sensor Loss Fault
6
RecChB OvTmp
Rectifier Channel B Over Temperature Fault
7
RecChB LoTmp
Rectifier Channel B Low Temperature Fault
8
RecChB FbrOp
Rectifier Heatsink Channel B Fiber Optic Cable disconnected Fault
9
RecChB Sens
Rectifier Channel B Sensor Loss Fault
10
Dvc AK/Snubb
Device anode-Cathode or Snubber Fault
11
Current Sens
Current Sensor Fault
12 Unused
13 Unused
14 Unused
15 Unused
Drive Fault Mask 4 [Drv Fault4 Mask]
Linear Number:
562
Default Value:
1111111111111111
Access Level:
Basic
Read/Write:
Read/Write
This parameter specifies the mask for the fourth fault word corresponding to drive protection. A ‘1’
represents an enabled fault; a ‘0’ represents a disabled fault. The bit assignment is:
Bit
Enum Text
Description
0
Inv OvrVolt
Inverter Over Voltage Fault
1
Drv Out Open
Drive Output Contactor Open Fault
2
SyncXferFail
Synchronous Transfer Failed
3
Tach Loss
Tachometer Loss Fault
4
MV Sys Test
Medium Voltage applied to drive in System Test Fault
5
MV Gate Test
Medium Voltage applied to drive in Gating Test Fault
6
InpCtctrOpen
Input Contactor Open Fault
7
OutCtctrOpen
Output Contactor Open Fault
8
BypCtctrOpen
Bypass Contactor Open Fault
9
No Out Ctctr
No Output Contactor Fault
10
Inp IsoOpen
Input Isolation Switch Open Fault
11
Out IsoOpen
Output Isolation Switch Open Fault
12
Byp IsoOpen
Bypass Isolation Switch Open Fault
13
Inp IsoClsd
Input Isolation Switch Closed Fault
14
Out IsoClsd
Output Isolation Switch Closed Fault
15
Byp IsoClsd
Bypass Isolation Switch Closed Fault
Содержание PowerFlex 7000
Страница 1: ...PowerFlex 7000 Medium Voltage AC Drive TECHNICAL DATA Firmware Version 7 xxx ...
Страница 2: ......
Страница 4: ...ii Table of Contents 7000 TD002A EN P September 2007 ...
Страница 44: ...1 40 Functional Description 7000 TD002A EN P September 2007 ...
Страница 244: ......
Страница 282: ...2 238 Alphabetical Index 7000 TD002A EN P September 2007 This page is intentionally left blank ...
Страница 346: ...3 58 Troubleshooting 7000 TD002A EN P September 2007 ...
Страница 349: ......