Parameter Descriptions
2-5
7000-TD002A-EN-P – September 2007
Rectifier Heat Sink Temp °F [Rec HSink Temp F]
Linear Number:
255
Minimum Value:
-40.0 F
Maximum Value: 212.0 F
Access Level:
Monitor
Read/Write:
Read
Only
This parameter specifies the rectifier heat sink temperature in degrees Fahrenheit.
Inverter Heat Sink Temp °C [Inv HSink Temp C]
Linear Number:
252
Minimum Value:
-40.0 C
Maximum Value: 100.0 C
Access Level:
Monitor
Read/Write:
Read
Only
This parameter specifies the inverter heat sink temperature in degrees Celsius.
Inverter Heat Sink Temp °F [Inv HSink Temp F]
Linear Number:
253
Minimum Value:
-40.0 F
Maximum Value: 212.0 F
Access Level:
Monitor
Read/Write:
Read
Only
This parameter specifies the inverter heat sink temperature in degrees Fahrenheit.
Air Filter Blockage [Air Filter Block]
Linear Number:
567
Minimum Value:
0.0 %
Maximum Value: 100.0 %
Access Level:
Basic
Read/Write:
Read
Only
This parameter specifies the amount of air filter blockage in %. An increasing value is an indication of air
filter blocking. The blockage is calculated from the measured
Convrter AirFlow
(447) and the nominal
converter air flow
Conv AirFlow Nom
(417). A drop in pressure sensor value is an indication of reduced
airflow in the drive due to a blocked air filter. The drive continuously monitors this value and will trip
before the air filter gets fully blocked.
Air Filter Allow [Air Filter Allow]
Linear Number:
568
Minimum Value:
0.0 %
Maximum Value: 100.0 %
Access Level:
Basic
Read/Write:
Read
Only
This parameter specifies the % allowable filter blockage before the drive will trip. A decreasing value is an
indication of air filter blocking.
Содержание PowerFlex 7000
Страница 1: ...PowerFlex 7000 Medium Voltage AC Drive TECHNICAL DATA Firmware Version 7 xxx ...
Страница 2: ......
Страница 4: ...ii Table of Contents 7000 TD002A EN P September 2007 ...
Страница 44: ...1 40 Functional Description 7000 TD002A EN P September 2007 ...
Страница 244: ......
Страница 282: ...2 238 Alphabetical Index 7000 TD002A EN P September 2007 This page is intentionally left blank ...
Страница 346: ...3 58 Troubleshooting 7000 TD002A EN P September 2007 ...
Страница 349: ......