Connecting the Kinetix 6000 Drive System
Wiring the Auxiliary Power Output (P2L) Connector
Line Interface Module (P2L connector)
Auxiliary Power Output (P2L) Connector
2094-AL
xx
S, -BL
xx
S, -XL75S-C
x
AUX
2_L2
AUX2_L1
AUX
1_L2
AUX
1_L1
1 2 3 4
Line Interface Module, Top
V
iew
(2094-XL75
S
-C
x
is shown)
P2L Pin
Signal
Recommended
Wire Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
Nm (lb-in)
1
AUX1_L1
0.2-4.0
(24-10)
7.0
(0.28)
0.5 - 0.6
(4.4 - 5.3)
2
AUX1_L2
3
AUX2_L1
4
AUX2_L2