In the example below, the sum of the IAM, AMs, and SM equal 500 W
of continuous shunt power.
Shunt Power Example (without external shunt)
In the example below, the system is identical to that shown in the
example above, except the Kinetix 6000 (2094-BSP2) shunt module is
wired to a Bulletin 1394 external shunt module. The IAM and AM
internal shunt power is disabled and the continuous shunt power is
equal to that of the external shunt module alone.
Shunt Power Example (with external shunt)
TIP
Shunt power adds up the same way for 460V (IAM, AM, and
SM) systems too.
Kinetix 6000 (230V) Shunt Power Example
500 W Continuous Shunt Power
SM (2094-BSP2) 200 W Shunt Module
AM (2094-AM02) No Internal Shunt
AM (2094-AM03) 50 W Internal Shunt
AM (2094-AM03) 50 W Internal Shunt
IAM (2094-AC16-M03) 200 W Internal Shunt
TIP
The external shunt disables the internal shunt capacity of 460V
(IAM, AM, and SM) systems too.
BULLETIN 1394 300W SHUNT MODULE
ALLEN-BRADLEY
FOR USE WITH 1394-SJT22-X SYSTEM MODULE
CAT.
PART
SER.
INPUT DC
INPUT AC
FOR FUSE REPLACEMENT USE:
BUSSMAN CAT. NO.
R
Shunt Module
Kinetix 6000 (230V) Shunt Power Example
900 W Continuous Shunt Power
Bulletin 1394 External Shunt Module
(1394-SR9AF) 900 W External Shunt
SM (2094-BSP2) 200 W Shunt Module
AM (2094-AM02) No Internal Shunt
AM (2094-AM03) 50 W Internal Shunt
AM (2094-AM03) 50 W Internal Shunt
IAM (2094-AC16-M03) 100 W Internal Shunt
Содержание Allen-Bradley Kinetix 6000
Страница 8: ...Publication 2094 UM001A EN P September 2006 8 Table of Contents...
Страница 18: ...Publication 2094 UM001A EN P September 2006 18 Start...
Страница 118: ...Publication 2094 UM001A EN P September 2006 118 Connecting the Kinetix 6000 Drive System...
Страница 144: ...Publication 2094 UM001A EN P September 2006 144 Configure and Startup the Kinetix 6000 Drive System...
Страница 168: ...Publication 2094 UM001A EN P September 2006 168 Removing and Replacing the Kinetix 6000 Drive Modules...
Страница 190: ...Publication 2094 UM001A EN P September 2006 190 Specifications and Dimensions...
Страница 256: ...Publication 2094 UM001A EN P September 2006 256 Integrating Resistive Brake Modules with Kinetix 6000 Drives...
Страница 265: ...Publication 2094 UM001A EN P September 2006 265 Notes...
Страница 266: ...Publication 2094 UM001A EN P September 2006 266 Notes...
Страница 267: ...Publication 2094 UM001A EN P September 2006 267 Notes...