Grounding Your
Kinetix 6000 System
All equipment and components of a machine or process system
should have a common earth ground point connected to chassis. A
grounded system provides a ground path for short circuit protection.
Grounding your modules and panels minimize shock hazard to
personnel and damage to equipment caused by short circuits,
transient overvoltages, and accidental connection of energized
conductors to the equipment chassis.
Grounding Your System to the Subpanel
The 2094 power rail (2094-PR
x
or 2094-PRS
x
) ships with a braided
ground strap, 100 mm (3.9 in.), that connects to the bonded cabinet
ground bus. Connect the other end to either the power rail ground
stud or mounting bracket ground stud, if mounting brackets are used.
Connecting the Braided Ground Strap Examples
ATTENTION
The National Electrical Code contains grounding requirements,
conventions, and definitions. Follow all applicable local codes
and regulations to safely ground your system.
For CE grounding requirements, refer to Agency Compliance on
page 16.
LIM
PRS
PR
LIM
PR/PRS
LIM
PRS
PR
LIM
PRS
PR
PR
PR
Ground Grid or Power
Distribution Ground
Bonded Cabinet
Ground Bus
Braided
Ground Strap
2094 Power Rail
(2094-PRS
x
shown)
Bonded Cabinet
Ground Bus
Bonded Cabinet
Ground Bus
2094 Power Rail
on 2094 Mounting Brackets
(2094-PRS
x
shown)
Line Interface Module
on 2094 Mounting Brackets
(2094-AL
xx
S shown)
Ground Grid or Power
Distribution Ground
Ground Grid or Power
Distribution Ground
Braided
Ground Strap
Braided
Ground Strap
Ground Stud
Ground Stud
Ground Stud
2094 Mounting Bracket
(2094-XNBRKT-1)
2094 Mounting Bracket
(2094-XNBRKT-1)
Содержание Allen-Bradley Kinetix 6000
Страница 8: ...Publication 2094 UM001A EN P September 2006 8 Table of Contents...
Страница 18: ...Publication 2094 UM001A EN P September 2006 18 Start...
Страница 118: ...Publication 2094 UM001A EN P September 2006 118 Connecting the Kinetix 6000 Drive System...
Страница 144: ...Publication 2094 UM001A EN P September 2006 144 Configure and Startup the Kinetix 6000 Drive System...
Страница 168: ...Publication 2094 UM001A EN P September 2006 168 Removing and Replacing the Kinetix 6000 Drive Modules...
Страница 190: ...Publication 2094 UM001A EN P September 2006 190 Specifications and Dimensions...
Страница 256: ...Publication 2094 UM001A EN P September 2006 256 Integrating Resistive Brake Modules with Kinetix 6000 Drives...
Страница 265: ...Publication 2094 UM001A EN P September 2006 265 Notes...
Страница 266: ...Publication 2094 UM001A EN P September 2006 266 Notes...
Страница 267: ...Publication 2094 UM001A EN P September 2006 267 Notes...