Replace RS-422 Motors with Ethernet Motors
The RS-422 MagneMover LITE motors can be replaced with Ethernet motors easily depend-
ing upon the location and mounting method for the motor. This example replaces one curve
and one straight motor from the loop using RS-422 motors that is shown in
Figure 16: Basic RS-422 Loop
Required Tools and Equipment
•
Torque wrench with the following bits:
•
T30 Torx. (v-brace screw)
•
10 mm Hex socket. (M6)
•
13 mm Hex socket. (M8)
•
Computer with an Ethernet port and a web browser.
•
System Node Controller Configuration File.
Remove Existing RS-422 Motors
1.
Turn off all electrical and pneumatic power to the MagneMover LITE transport system
where the motors are being replaced.
2.
Remove the RS-422 motors from the transport system as shown in
, see
Figure 17: Basic RS-422 Loop with Motors Removed
Relay
HLC &
Node
Controller
RS-422 Motor
RS-422 Motor
Loop Transport System:
Two RS-422 Connections,
One Path
RS-422 Motor
RS-422 Motor
P1M1
P1M2
P1M3
P1M4
P1M5
P1M6
P1M7
P1M8
RS-422
Motor
RS-422
Motor
RS-422
Motor
RS-422
Motor
Host
Controller
Enet
Switch
HLC &
Node
Controller
Relay
RS-422 Motor
RS-422 Motor
RS-422 Motor
P1M1
P1M2
P1M3
P1M4
P1M5
P1M6
RS-422
Motor
RS-422
Motor
RS-422
Motor
Host
Controller
Enet
Switch