Maintenance
Repair
MagneMover LITE Service Manual
101
Rockwell Automation Publication MMI-UM037A-EN-P - April 2020
Replace Power Supply Fuses
Fuses must be replaced if they become damaged.
Required Tools and Equipment
•
Small flat-blade screwdriver.
•
5 x 20 mm, 250V, 10 A time-lag fuses (Littelfuse 218 or equivalent).
•
6.3 x 32 mm, 250V AC, 10 A ceramic slow blow fuses (Littelfuse 326 or equivalent).
Procedure
Figure 34: Power Supply Fuse Locations
CAUTION
High Voltage Hazard
100–240 VAC, 8.5 A
AC power must be disconnected before servicing.
CAUTION
Double Pole/Neutral Fused
AC power must be disconnected before servicing.
F3
LOGIC
T, 250V, 10A
F1
PROPULSION 1
T, 250V, 10A
LOGIC
PROPULSION
F2
PROPULSION 2
T, 250V, 10A
SEE M
AN
UA
L F
O
R F
IL
TER
M
AI
NT
EN
AN
CE
GND
J4 DC ENABLE
(SEE MANUAL FOR PINOUT)
36 VDC
300W / 8A MAX
36 VDC
300W / 8A MAX
J1
J2
GND
V+
PROPULSION
V+
LOGIC
V-
RETURN
V+
LOGIC
V-
RETURN
V+
PROPULSION
Power Entry Module
DC Fuse
Rear View
Front View
Holders