Rockwell Automation Publication MMI-UM037A-EN-P - April 2020
General Cleaning
General cleaning of the MagneMover LITE transport system consists of cleaning the transport
system surfaces as described.
Required Tools and Equipment
•
Disposable gloves.
•
Microfiber cleaning cloth.
•
Deionized water.
•
Isopropyl alcohol (optional).
Procedure
1.
Stop all motion on the sections of the MM LITE transport system to be cleaned.
2.
While wearing gloves, clean all exposed transport system surfaces and cables with a
clean microfiber cloth slightly dampened with deionized water or Isopropyl alcohol.
Wipe in the direction of the grain on all surfaces that have a grain.
3.
Make sure that all components are dry.
4.
Resume motion on the sections of the MM LITE transport system that were stopped.
Spray Cleaning
Spray cleaning the MagneMover LITE motors or the material being moved on the motors
consists of providing a constant water spray as defined by IP65.
1.
Make sure that all components that are not IP65 washdown compatible (power sup-
plies, node controllers, and so on) are appropriately covered.
2.
If only the motors are being cleaned, stop all motion on the sections of the MM LITE
to be cleaned. If material in transit is being cleaned, motion does not need to be
stopped, simply adjust the speed of the pucks to make sure of proper cleaning of the
material.
NOTICE
Only the motors, pucks, and magnet arrays are IP65 washdown compatible.
Make sure that all components that are not IP65 washdown compatible
(power supplies, node controllers, and so on) are not exposed to water spray.