Maintenance
Repair
88
MagneMotion
Rockwell Automation Publication MMI-UM037A-EN-P - April 2020
8.
Remove the remaining puck from the fixture and store it in its original shipping con-
tainer, or wrap it in bubble-wrap, for protection. Do not move one puck over, or near,
the other puck.
9.
Service the pucks as required, see
Replace Glide Puck Wear Surfaces
.
Re-assemble Tandem Puck Assembly
1.
Place the tandem puck linkage plate installation fixture (shown in
surface.
2.
Place one puck assembly in the left side of the fixture as shown in
Figure 25: Place First Glide Puck in Fixture
3.
Hold the left puck in place and place the right puck in the fixture keeping it as far away
from the left puck as possible as shown in
. Do not move one puck over, or
near, the other puck.
CAUTION
Strong Magnets
To avoid injury from strong magnetic attractive
forces:
•
Handle only one puck at a time.
•
Do not place any body parts, such as fingers,
between the puck and any ferrous material or
another magnet array.
•
Pucks not being used must be secured individu-
ally in isolated packaging.
Puck
Installation
Fixture