SECTION 6—FAULT MESSAGES
Stop-Time Measurement Device
Display Message
Cause/Solution
MEMORY FULL
The data for 30 machines is in memory (10 measurements/machine). Print or
transfer data in
MM MEASURING DATA MANAGEMENT
section and delete
all data after this step is complete.
NO DATA IN MEMORY
There is no data available. Perform measurement tests and data will be stored
in memory.
ACTUATOR FEED BACK OVERFLOW
The actuator is defective or the delay time is not correct. Carry out an actuator
test in the M
M TEST FUNCTION AND SERVICE
section and try another
measurement test. If this message continues, recharge the battery.
MEASURING DEVICE DOES NOT
ACCEPT ANY COMMANDS
Press all three function operation buttons simultaneously to reboot
OTHER FAILURES
Reset factory default settings in
MM TEST FUNCTION AND SERVICE
.
Delete all measurement data in the
MM MEASURING DATA MANAGEMENT
section.
STORED DATA SHOWS INCORRECT
FORMATTING
Delete all measurement data in the
MM MEASURING DATA MANAGEMENT
section.
PRINTER SHOWS MISTAKES
PRINTER OR ACTUATOR IS NOT
WORKING CORRECTLY
Check the cable connection.
LOW BATTERY
Charge the battery.
Table 6.1
SECTION 7—REPLACEMENT PARTS
Part No.
Description
DCL-034
STOP-TIME meter
DCL-043
Sensor
DCL-044
Actuator
DCL-045
Flag
DCL-046
Sensor base magnet
DCL-047
Magnet for ram attachment
Part No.
Description
DCL-048
Allen wrench
DCL-049
Actuator spacer
DCL-050
Actuator pushbutton plate
DCL-051
Printer
DCL-052
Cord and plug for printer
DCL-053
Insturction label