![Rockford Systems Stop-Time Measuring Device Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/rockford-systems/stop-time-measuring-device/stop-time-measuring-device_instruction-manual_1474306026.webp)
Rockford Systems, LLC
1-800-922-7533 (U.S.A. only)
26
Press
ENTER
to go into the submenu.
The display reads:
P3 MEASURING DIRECTION DOWN
This is the factory setting. To change the factory setting,
press
ENTER
. The display reads:
P3 MEASURING DIRECTION UP
Press
▼
to go to the next setting.
P3 MEASUREMENTS
The display reads:
P3 MEASUREMENTS/MACHINE 000
This is the factory setting that allows unlimited
measurements per machine with no data stored. To change
the factory setting, press
ENTER
. The display reads:
P3 MEASUREMENTS CHANGE 000
Use the
▲
and
▼
buttons to scroll through the numbers
001 - 010
. Press
ENTER
at the desired selection. The
display reads:
P3 MEASUREMENTS MACHINE XXX
(XXX = the programmed test number)
Press
▼
to go to the next setting.
P3 MEAS. MODE
The display reads:
P3 MEAS. MODE MANUAL
This is the factory setting. To change the factory setting,
press
ENTER
. The display reads:
P3 MEAS. MODE AUTOMATIC
Press the
▼
button. The display reads:
P3 AUTO M. MODE DELAY 005S
This is the factory setting. To change the factory setting,
press
ENTER
. The display reads:
P3 AUTO M. MODE CHANGE 005S
Use the
▲
and
▼
buttons to scroll through the numbers
000 - 255
. Press
ENTER
at the desired selection. The
display reads:
P3 AUTO M. MODE DELAY XXXS
(XXX = the programmed test number)
Press
▼
to go to the next setting.
P3 SPM METHOD
The display reads:
P3 SPM METHOD TEACH-IN
This is the factory setting. To change the factory setting,
press
ENTER.
The display reads:
P3 SPM METHOD MANUAL
Press
ENTER
again and the display reads:
P3 SPM METHOD TEST STROKE
Continue to press
ENTER
until the desired setting is
displayed. Press
▼
to select it and go to the next setting.
P3 MACHINE NO(number)/MACHINE ID
The display reads:
P3 MACHINE NO (number) NO
This is the factory setting. To change the factory setting,
press
ENTER.
The display reads:
P3 MACHINE NO (number) YES
If
YES
is chosen here, when the
MM STOP-TIME
MEASURING
menu is displayed, there will be a prompt to
enter a machine ID number (see page 20).
Press
▼
to go to the next setting.
P3 QUIT
The display reads:
P3 QUIT
Press
ENTER
to quit the Parameter 3 submenu and to
return to the
MM PARAMETER 3 MEASURING
.
Press the
▲
or
▼
buttons to go to the next MM program
that requires programming or go to the
MM STOP-TIME
MEASURING
program to do a test.
MM PARAMETER 3
MEASURING
SECTION 5—PROGRAMMING
Stop-Time Measurement Device