(See page 25 for step-by-step 
instructions.)

P2 SAFETY DEVICE METHOD

: This function determines 

how the stop-time measuring actuator will stop the 
machine. 

TWO-HAND, OTHERS

 is used when the 

STM test is performed with the actuator depressing the 
initiating means. The 

LIGHT CURTAIN

 setting is used 

when the STM test is performed with the flag attached to 
the actuator. The flag is used to interrupt the sensing field 
of the light curtain. If a 

LIGHT CURTAIN

 is used, the light 

curtain 

RESPONSE TIME

 and 

RESOLUTION 

(Minimum 

Object Sensitivity) should be entered as described below. 

P2 APPROACH SPEED

: This function determines the hand 

speed constant value used in the stop-time measuring 
calculation. The factory setting is 63 IN/S (inches/second), 
using the OSHA formula as shown on page 7. 

P2 RESPONSE TIME

: When the 

P2 SAFETY DEVICE

 

METHOD

 is set to 

LIGHT CURTAIN

, the light curtain 

response time is programmed in this setting for use in the 
stop-time measuring calculation. If the flag on the actuator 
is used to interrupt the light curtain and stop the machine, 
enter 00.0 because the response time of the light curtain 
will automatically be measured. 

P2 RESOLUTION

: When the 

P2

 

SAFETY

 

DEVICE

 

METHOD

 is set to 

LIGHT

 

CURTAIN

, the depth penetration 

factor (based on the minimum object sensitivity) is required 
when using the ANSI safety distance formula as shown on 
page 8. If using the OSHA formula, do the same as ANSI, 
even though this added distance is not part of the formula. 

(See page 26 for step-by-step 
instructions.)

P3

 

MEASURING

 

DIRECTION

: This function determines 

if the stop-time measuring actuator stops the machine 
on the downstroke or on the upstroke. The downstroke 
is usually used to determine the safety distance. The 
upstroke stopping time may be useful when adjusting the 
counterbalance.

MM PARAMETER 2 
SAFETY DISTANCE

When in the 

P3 SPM

 

METHOD 

(described below)and 

using either the 

MANUAL

 or

 TEACH IN

 mode,the actuator 

can be released either the first or the second time the 
cable sensor reaches the start point of the measurement, 
stopping the slide motion at approximately 90°or 270°.

P3 MEASUREMENTS MACHINE

 

000: 

This function 

determines the number of measurements that will be taken 
per machine. The factory setting of 000 allows unlimited 
measurements but does not store any data. To set the 
number of tests per machine, select a number between 

001-010

. A maximum of 10 tests per machine (maximum 

of 30 machines) may be taken. Data will only be stored 
when a number between 

001-010

 is selected. After the 

selected number of tests are completed, the device starts 
measurements for the next machine. 

P3 MEAS. MODE

: This function determines the method 

used to advance to the next measurement within the 

MM 

STOP-TIME

 

MEASURING

 menu. In the manual mode, the 

user must press 

ENTER

 to advance to the next step in the 

measuring process. In the automatic mode, after taking 
an STM reading, the unit will automatically advance to the 
next measurement after counting down through the preset 
time (see page 26 to adjust time).

P3 SPM METHOD

: This function determines at what point 

in the stroke the test will be performed. This is referred to 
as the start point of measurement. 
In the 

TEACH-IN

 mode, the start point of measurement is 

entered into the STM unit at a specific point in the 

MM STOP-

TIME MEASURING

 menu. The cable sensor must be at the 

desired start point of measurement when 

ENTER

 is pressed. 

In the 

MANUAL

 mode, the operator enters the stroke length 

when prompted in the 

MM STOP-TIME MEASURING

 menu. 

In the 

TEST STROKE

 mode, the highest SPM (Strokes Per 

Minute) of the crankshaft on the down-stroke is measured. 

P3 MACHINE NO/MACHINE ID:

 This function determines 

if a machine ID No. will be required. If this is set to 

YES

a prompt for the machine ID No. appears on the screen in 
the 

MM STOP-TIME MEASURING

 menu. If this variable 

is set to NO(factory setting), each machine is referred to 
by a sequential No. and a machine ID No. is not required.

MM PARAMETER 3 
MEASURING

SECTION 5—PROGRAMMING

Stop-Time Measurement Device

Continued on next page.)

Содержание Stop-Time Measuring Device

Страница 1: ...G THE STOP TIME MEASURING DEVICE INSTRUCTION MANUAL FOR STM STOP TIME Measuring Device 5795 Logistics Parkway Rockford Illinois 61109 Toll Free 1 800 922 7533 Phone 815 874 7891 Fax 815 874 6144 Web S...

Страница 2: ...17 19 MM STOP TIME MEASURING 20 MM POWER DOWN SWITCH OFF 20 MM TEST FUNCTION AND SERVICE 21 MM MEASURING DATA MANAGEMENT 22 MM PRINT MANAGER 23 MM PARAMETER 1 BASIC SETTINGS 24 MM PARAMETER 2 SAFETY D...

Страница 3: ...agement to operators since only as a group can any operational problems be identified and resolved It is everyone s responsibility to implement and communicate the information and material contained i...

Страница 4: ...Federal Regulations Subpart O Concepts and Techniques of Machine Safeguarding OSHA 3067 Revised 1992 These publications can be acquired by contacting US Department of Labor Occupational Safety and He...

Страница 5: ...0537 Dies Setup and Removal of Forging Hammer 12304 0716 Drill Presses Metalworking 12304 0335 Drills Portable Reamer 12304 0497 Drop Hammers Steam 12304 0720 Electrical Controls for Mechanical Power...

Страница 6: ...erstood For example if a light curtain or two hand control is going on a mechanical power press punch press with a part revolution clutch the following are the requirements from OSHA SUBPART O 1910 21...

Страница 7: ...ined by the following formula Ds 63 inches second x Ts Where Ds minimum safety distance inches 63 inches second hand speed constant and Ts stopping time of the press measured at approximately 90 posit...

Страница 8: ...turer If beam blank outs or floating window features are used these figures should be added to the object sensitivity figure No increase in safety distance is required for fixed channel blanking appli...

Страница 9: ...takes a machine to stop after a signal is given It is mainly used on reciprocating stroking or cycling machines such as mechanical and hydraulic presses or press brakes With optional accessories it ca...

Страница 10: ...cles on the meter Set the sensor on the bed of the machine and attach the magnet and cable to the slide or other reciprocating machine component With power to the meter inch the machine to a point in...

Страница 11: ...power Actuator Auto hand 8 5 8 Lx 1 3 8 H x 1 3 8 D Power Supply 5 15 VDC from STM meter Weight Total weight without printer 8 1 2 lbs Sensor Dimensions 5 1 8 Lx 2 1 2 D x 2 H Fixture Magnetic pads St...

Страница 12: ...reen light indicates that the battery is charging A flashing green light indicates when charging is done When the battery is low the display indicates Low Battery and allows 5 10 minutes of further te...

Страница 13: ...zone at the proper point in the stroke of the machine Hand Speed Constant The generally agreed upon speed at which the operator s hands move toward the point of operation Defined by OSHA as 63 inches...

Страница 14: ...am or platen Follow the step by step procedures in the next section for this test Stopping times and safety distance will vary due to the inaccuracies in your arm movement USING THE STOP TIME DEVICE B...

Страница 15: ...ill interrupt the sensing field of the light curtain See photos Hold the actuator just outside the sensing area of the light curtain See photo at right When the actuator releases the flag should penet...

Страница 16: ...ABLE TR P1 LANGUAGE ENGLISH P1 MEAS UNIT INCH P1 DISPLAY LIGHT ON P1 QUIT P2 SAFETY DEVICE TWO HAND OTHERS CURTAIN 000 MS CURTAIN 00 0 IN SPEED 063 IN S P2 QUIT SM MACHINE 001 SET SPM POSITION TEACH I...

Страница 17: ...on mechanical power presses Next enter this point to give the stop signal Refer to the MM STOP TIME MEASURING section on page 20 for details MANUAL The start point of the measurement can be set manua...

Страница 18: ...ge 22 for step by step instructions DM PRINT DATA FROM MEMORY This function provides power to the printer when it is connected to the RS 232 port on the front of the unit This function also prints the...

Страница 19: ...L or TEACH IN mode the actuator can be released either the first or the second time the cable sensor reaches the start point of the measurement stopping the slide motion at approximately 90 or 270 P3...

Страница 20: ...complete press ENTER to return to MM STOP TIME MEASURING The display reads MM POWER DOWN SWITCH OFF Press ENTER to shut down the meter The display reads POWER OFF The device automatically shuts off Pr...

Страница 21: ...s OR Press to go to the next setting TF DEFAULT SETTINGS The display reads TF DEFAULT SETTINGS Press ENTER to access default settings The display reads TF DEFAULT SETTINGS NO Use the or buttons to tog...

Страница 22: ...twice to go to the next setting DM DELETE ALL DATA IN MEMORY The display reads DM DELETE ALL DATA IN MEMORY Press ENTER The display reads DM DELETE ALL DELETE ALL NO Press the or buttons to toggle bet...

Страница 23: ...e the setting to YES Press to go to the next setting PM PRINT COPIES The display reads PM PRINT COPIES SINGLE This is the factory setting Press ENTER to change the setting to DOUBLE Press to go to the...

Страница 24: ...the factory setting To change the factory setting press ENTER and the display reads P1 SENSOR SELECT DIGITAL CABLE TR Press to go to the next setting P1 LANGUAGE The display reads P1 LANGUAGE ENGLISH...

Страница 25: ...equires programming or go to the MM STOP TIME MEASURING program to do a test ALTERNATE SETTING PROGRAMMING After selecting P2 SAFETY DEVICE LIGHT CURTAIN press to go to the next setting P2 RESPONSE TI...

Страница 26: ...MODE CHANGE 005S Use the and buttons to scroll through the numbers 000 255 Press ENTER at the desired selection The display reads P3 AUTO M MODE DELAY XXXS XXX the programmed test number Press to go t...

Страница 27: ...MEASURING DEVICE DOES NOT ACCEPT ANY COMMANDS Press all three function operation buttons simultaneously to reboot OTHER FAILURES Reset factory default settings in MM TEST FUNCTION AND SERVICE Delete a...

Страница 28: ...ted q Full Credit q 25 Restocking q Repair Return q Warranty Replacement Reason for return describe in detail Return Materials Authorized By Date ORDER FORM FOR SIGNS AND LITERATURE This instruction m...

Отзывы: