SECTION 5—PROGRAMMING
Stop-Time Measurement Device
Continued on next page.)
This function is used for
measurement testing. See page
20 for step-by-step instructions.
This function manually turns
the meter off. Seepage 20 for
step-by-step instructions.
(See page 21 for step-by-step
instructions.)
TF TEST STROKE
: The test stroke is used to obtain the
highest strokes per minute. Start at TDC(Top Dead Center)
and press
ENTER
. When prompted, perform a single
stroke. The STM unit will measure the highest velocity
point in the stroke. This point will then be used to take sub
sequent measurements when
P3 SPM METHOD
is set to
TEST STROKE.
TF ACTUATOR TEST FEEDBACK CONTROL:
This
function provides the STM unit with the response time of
the actuator. This function is performed only once when
the actuator is new, or if there are mechanical changes to
the actuator.
TF BATT. DRAIN & CHARGE:
This function powers down
the STM unit and depletes any remaining charge on the
batteries. The batteries should then be recharged. While
the battery is discharging, the LED light will flash slowly
(two-second intervals). A solid green light indicates the
device is charging. When the device is done recharging,
the LED light will flash quickly (one-second intervals). This
procedure should be performed each time the battery is
recharged to lengthen the life of the battery.
TF DEFAULT SETTINGS:
Performing this function restores
the factory default settings for all program variables. (See
pages 16 and 21.)
(See page 22 for step-by-step
instructions.)
DM PRINT DATA FROM MEMORY:
This function provides
power to the printer when it is connected to the RS-232
port on the front of the unit. This function also prints the
header information and/or the data stored in memory.
DM DATA TRANSFER TO COMPUTER:
This function was
not supported at the printing of this manual.
(Software Ver. 2.07.)
DM DELETE ALL DATA IN MEMORY:
This function clears
all measurement data that is currently in memory.
(See page 23 for step-by-
step instructions.)
PM PRINT HEAD:
This function turns on the print header
setting. Setting this variable to YES adds the header
information to the top of each machine printout.
PM PRINT VALUES
: This function turns on the print values
setting. Setting this variable to YES enables the printer. To
print data, see
MM MEASURING DATA MANAGEMENT
on
page 22 for details.
PM PRINT COPIES:
This function provides the choice of
printing single or double copies.(See page 24 for step-by-
step instructions.)
P1 TIME SETTING:
This function is used to set the time.
P1 DATE SETTING:
This function is used to set the date.
P1 SENSOR SELECT:
This function is used to set the
sensor type. The standard (default) setting for this variable
is
ANALOG CABLE TR.
Do not change this setting unless a
digital sensor is connected.
P1 MEAS. UNIT
: This function is used to set the calculated
measurements in inches or metric. The standard (default)
setting for this variable is
INCH
.
P1 DISPLAY LIGHT:
This function is used to turn the
display backlight on or off. Turn the light
ON
when operating
in low ambient light conditions.
MM STOP-TIME
MEASURING
MM POWER DOWN
SWITCH OFF
MM TEST FUNCTION
AND SERVICE
MM MEASURING
DATA MANAGEMENT
MM PRINT MANAGER
MM PARAMETER 1
BASIC SETTINGS