Rockford Systems, LLC
1-800-922-7533 (U.S.A. only)
20
Press
ENTER
.
The display reads:
000.0IN 0000MS
WAIT SD000.0IN
A
START
message will appear. Start the stroke of the
machine using both hands. In one hand use the hand-held
actuator to depress one of the run/inch buttons with the
round pushbutton plate on the actuator (see Photo 3.3 on
page 14). The actuator will release and cause the stroke
or cycle to be interrupted which will stop the movement
of the ram.
The display reads the calculated safety distance and
stopping time:
004.5IN 0250MS
001 SD015.75IN
These numbers indicate the calculation of the
measurement:
IN
is the set point of the sensor;
MS
is the
stopping time in milliseconds;
001
is the test number;
SD
is the safety distance in inches.
To take another measurement on the same machine,
return to
**
at the bottom of the previous column. Since
the factory setting is
000
, unlimited measurements may
be taken per machine, however no data will be stored.
To change the factory setting, go to
MM PARAMETER 3
MEASURING, P3 MEASUREMENTS/MACHINE 000
(see
page 26 for instructions).
If an unusual measurement is displayed, press the
▼
button
to repeat that measurement.
SKIP
will appear on the display
and a new measurement can then be taken. When all
measurements are complete, press
ENTER
to return to
MM
STOP-TIME MEASURING
.
The display reads:
MM POWER DOWN; SWITCH OFF
Press
ENTER
to shut down the meter.
The display reads:
POWER OFF . . .
The device automatically shuts off.
Press
ENTER
to go into the submenu.
The display reads:
SM MACHINE 001
Press
ENTER.
(GO TO
✱
)
OPTION
If machine ID yes was selected in the
MM PARAMETER
3
MEASURING
section, the display reads:
SM MACHINE OO1 ID– – – – – – – –
An ID number must be entered. Press
ENTER
to bring
the cursor under the first character. Use the
▲
and
▼
buttons to scroll through numbers (0 - 9), letters (A- Z),
and symbols ( . - + # and blank space). Press
ENTER
to confirm each choice and to go to the next character.
Repeat the procedure for all eight characters.
Press
ENTER
to go to the next setting.
The display reads:
SET SPM POSITION
TEACH-IN
Attach the cable and magnet to the ram and inch the
ram, platen, etc., to the position where a stop signal is
required. (On mechanical power presses and according
to OSHA requirements, this setting is at the 90°position
of crankshaft rotation, or at the halfway point in the
downstroke. Consult other standards for different settings.)
Press
ENTER.
The display reads:
SET SPM POSITION
TEACH 000.0IN
Press
ENTER
.
The display reads:
000.0IN 0000MS
DOWN SD000.0IN
Bring the ram to top dead center of crankshaft rotation or
to full open position. Cock the hand-held actuator.
MM STOP-TIME
MEASURING
✱
MM POWER DOWN
SWITCH OFF
**
(Continued on next page.)
SECTION 5—PROGRAMMING
Stop-Time Measurement Device