ENGLISH
76
Picture 14 - Rear sight of the plinth of the wood
fired cooker and specifies for the con-
nection with the air intake.
C
B
A
H
B
WARNING! Aspiring hoods or extracting air fans in the room may generate problems
to the device if there is not a suited air intake or in case of air intake sub-dimensioned.
WARNING! For the correct working of the wood fired cooker verify that the passage of
comburent air is not obstructed or, in case of connection with external air intake, that the
air aspiration grill is not obstructed.
External air entry
Table 4 - Dimensions for the connection of the external
air intake.
RNE 50
RNVE 50
RNI 60
RNVI 60
95
95
95
95
64
64
64
64
367
367
467
467
211
211
211
211
95
95
95
95
Models
A
B
C H
ø
Dimensions in mm
The electric connection of the cookers allows the
working of the fans placed on the sides and the
lighting of the oven lamp. The connection to AC
power must be done by experienced people and
according with existing laws. The installer is re-
sponsible of the correct connection according with
safety rules. To make the connection, you have to
connect an electric cable to the terminal board
placed in the rear side of the cooker. Must be done
the correct connections of line, neutral and earth
as described in the picture 16. The cable and every
other electric device added must be dimensioned
for the electric load to sustain and must not be
in contact with points 50° C hotter than ambient
temperature.
2.13
ELECTRIC CONNECTIONS
Picture 15 - Position of the terminal board for the
connection to the network.