Installation: Assembly, connection and start-up
129
In
st
al
la
tio
n
Command summary
Each start-up procedure is confirmed with a signal tone
. The next step of the start-up can be performed after the
signal tone.
ii
represents the index (00 to 99)
nn represents the call number of the telecommunication system subscriber
(1 to 6 digits)
X
represents one digit (0 to 9)
[ ] factory settings
Start-upprocedure
Meaning
10 ii {nn}
Store call number in memory location ii.
If not call number is specified, memory location ii is deleted.
11 ii
Select TwinBus telegram for memory location ii. A speech connection to the door
is set up. After the speech connection has been terminated using key
a ten
second time window opens. Door calls and floor calls that are received during this
time window are stored in the call memory. The operators at the door and the
telephone hear the positive acknowledgement tone.
12 ii
Delete TwinBus telegram from call memory.
19 ii
Check contents of call memory:
/
negative acknowledgement tone: memory location occupied.
✔
positive acknowledgement tone: memory location available.
90 XXXX
Change PASS code
[0000]
91 X
Set switching door opening contact time (1 to 9 seconds)[3]
92 X
Door opener release (0/1) [on]
93 X
Privacy function on/off (1/0)[off]
94 X
Setup numeric selection via code lock transmitter (0/1)[on]
95 XX
Set maximum call time (10...99 seconds)[25]
96 XXX
Set maximum busy time (030 to 180 seconds)[060]
97 1234
Initialize configuration memory to delivery condition (except signal and break
times)
98 XXXX
Set individual number for switching commands (0000...9999)[0000]
*
*
Содержание TWINBUS
Страница 2: ...2 ...
Страница 41: ...Installation Assembly connection and start up 41 Installation 00042 0 ...
Страница 156: ...Installation Installation Assembly connection and start up 156 ...
Страница 193: ...Notes 193 ...
Страница 194: ...Notes 194 ...
Страница 195: ...Notes 195 ...
Страница 196: ...Notes 196 ...