Inst
alla
tion
Installation: Assembly, connection and start-up
118
Starting up
The number of connected cameras must be set using the camera selector switch (DIP switch).
The camera selector switch can be operated in different operating modes. The desired operating mode must be set
using the operating mode switch (1). If operating mode (2) is used, the time setting via operating mode 0 must be
performed first.
Operating modes
0
Time setting
Setting the automatic camera switching time for operating mode 3.
1
Test mode
The camera changeover switch can be manually tested using button Z.
2
Selection mode
The camera is selected at the indoor video station by pressing a button with a fixed assignment. The camera
connected to terminals Va1 and Vb1 is activated when the bell button is pressed.
3
Automatic cycle
The cameras are switched over (time controlled).
4
Manual cycle
The cameras are switched over using the on-screen display on the indoor video station.
5
Actuation of cameras 1 4788 and 1 4789
The cameras are switched over using the on-screen display on the indoor video station. The camera module is
actuated by pressing the button again within 20 seconds of switching over.
Operating elements
1. Operating mode switch
2. Camera selector switch
3. LED, function indicator
4. Button Z, time setting switch
00249-1
Содержание TWINBUS
Страница 2: ...2 ...
Страница 41: ...Installation Assembly connection and start up 41 Installation 00042 0 ...
Страница 156: ...Installation Installation Assembly connection and start up 156 ...
Страница 193: ...Notes 193 ...
Страница 194: ...Notes 194 ...
Страница 195: ...Notes 195 ...
Страница 196: ...Notes 196 ...