Rinnai M
-
Series Condensing Boiler Combi Manual
33
The instructions below apply to concentric
vent sizes 2 in. x 4 in. and 3 in. x 5 in.
Horizontal Wall Terminations
Vertical Roof
Terminations
2 in. x 4 in.
and
3 in. x 5 in.
2 in. x 4 in.
and
3 in. x 5 in.
Install the venting termination according to the diagrams and instructions in this manual. Slope the
venting 1/4 in. per foot toward the appliance according to the vent manufacturer
’
s installation
instructions. Dispose of condensate per local codes.
IMPORTANT
Remove the vent top (slightly twist
counter
-
clockwise and pull up). Discard
vent top if desired.
Pull up
Slightly twist counter
-
clockwise
Insert the concentric adapter and rotate
clockwise until locked in place.
Содержание M Series
Страница 96: ...96 Rinnai M Series Condensing Boiler Combi Manual Heat Exchanger ...
Страница 98: ...98 Rinnai M Series Condensing Boiler Combi Manual Hydraulic Parts Pipes ...
Страница 101: ...Rinnai M Series Condensing Boiler Combi Manual 101 Electrical Components Solo Only ...
Страница 113: ...Rinnai M Series Condensing Boiler Combi Manual 113 ...
Страница 114: ...114 Rinnai M Series Condensing Boiler Combi Manual ...
Страница 122: ...122 Rinnai M Series Condensing Boiler Combi Manual 800000063 03 6 2019 ...