Confirm that the electricity is supplied from a 120 VAC, 60 Hz power source and is in a
properly grounded circuit.
□
Confirm that an extension cord or adapter plug has NOT been used with the boiler.
□
Confirm connection terminals are connected correctly.
Devices such as the room thermostat and outdoor temperature sensor are
connected to the connection terminal. The connection terminals are located on
the top and back of the controller.
To access the controller, remove the front panel (see section
“3.7
How to Remove
the Front Panel
”
for detailed instructions).
120 V power supply to boiler
DO NOT USE
This terminal is for Rinnai
-
use only and
not for use in any installation
System Pump Relay
Energized on a call for heat
Controller Top Connections
External
safety
contact
Remove
jumper
to use
DO NOT
USE
Outdoor
temperature
sensor
DO NOT
USE
Room
thermo-
stat
(On/Off
thermo-
stat or
control)
DO NOT
USE
For Rinnai
Use Only
For Rinnai
Use Only
For Rinnai
Use Only
DO NOT
USE
Not for
use in this
boiler
Controller Back Connections
Controller
DO NOT USE
This terminal is for Rinnai
-
use only and
not for use in any installation
Содержание M Series
Страница 96: ...96 Rinnai M Series Condensing Boiler Combi Manual Heat Exchanger ...
Страница 98: ...98 Rinnai M Series Condensing Boiler Combi Manual Hydraulic Parts Pipes ...
Страница 101: ...Rinnai M Series Condensing Boiler Combi Manual 101 Electrical Components Solo Only ...
Страница 113: ...Rinnai M Series Condensing Boiler Combi Manual 113 ...
Страница 114: ...114 Rinnai M Series Condensing Boiler Combi Manual ...
Страница 122: ...122 Rinnai M Series Condensing Boiler Combi Manual 800000063 03 6 2019 ...