background image

MODEL: COMPACT

INSTALLATION, OPERATION AND SERVICING INSTRUCTIONS

Calomax Limited

Lupton Avenue, Leeds LS9 7DD

Tel. 0113 249 6681 Fax. 0113 235 0358

e-mail: [email protected]        www.calomax.co.uk

Please read these 
instructions carefully 
before operating your 
boiler for the first time

Issue 10

21/12/07

DCR 760

Содержание COMPACT

Страница 1: ...STRUCTIONS Calomax Limited Lupton Avenue Leeds LS9 7DD Tel 0113 249 6681 Fax 0113 235 0358 e mail service calomax co uk www calomax co uk Please read these instructions carefully before operating your...

Страница 2: ...or assistance in finding a suitable engineer in your area visit our website www calomax co uk contact our service department on 0113 249 6681 or e mail service calomax co uk CHECK LIST Before commenci...

Страница 3: ...inless steel or non ferrous materials providing maximum resistance to corrosion CONSTRUCTION MODEL A B C DRY WEIGHT WORKING WEIGHT Compact mm 415 285 226 8 5 Kg 14Kg B A C DIMENSIONS AND WEIGHTS The b...

Страница 4: ...be at operating temperature indicated by the Wait Ready light showing a solid not flashing colour When the boiler is full and ready the light will be orange and when the boiler is only part full but r...

Страница 5: ...20 minutes and the solenoid valve has been disabled to prevent damage to the solenoid coil through overheat To re energise the solenoid the unit must be disconnected from the electrical supply and the...

Страница 6: ...on the electrical supply to the boiler General function The printed circuit board PCB controls the heating and filling functions of the boiler by monitoring the thermistor and level sensors The PCB al...

Страница 7: ...d Includes nuts washers etc Exploded parts view To be read in conjunction with the spare parts list 3 Probe assemblies in machine 3 5 6 7 8 9 10 11 12 13 14 15 16 Excludes insulation pieces element et...

Страница 8: ...SDTWDK with drain outlet Counter insertion plastic moulded drip tray Ref PDTWDK with drain outlet Fused spur time switch Ref 7DFST Max 3kW For more information visit our website at www calomax co uk o...

Страница 9: ...E PARTS Refer to centre pages for location NB Not to scale GTT CBTS CBTSS COMPMFK DOTTK COMSV CAP330 NBE2HK CASLPK TAP TOP ASSEMBLY TAP CUP WASHER TAP SPRING TAP SLOTTED STEM PLASTIC MOULDED FASCIA KI...

Страница 10: ...ace element Replace Circuit Board Overflows Dirt in solenoid valve Level sensors require de scaling or replacing Printed circuit board faulty Clean solenoid filter or replace solenoid work the boiler...

Страница 11: ...ack to base warranty Some factors are beyond our control and would invalidate the warranty offered These include Incorrect installation High Low water pressure Incorrect voltage supply Accidental dama...

Страница 12: ...Page 22 Page 23 SERVICE AND MAINTENANCE HISTORY SERVICE AND MAINTENANCE HISTORY...

Страница 13: ...from tap Stan dard nozzle 2 5 Litres Minute Voltage 220 240 V ac 50 60 Hz Power rating 2kW MAX PLEASE ENTER SERIAL NUMBER FOR FUTURE REFERENCE Note All measurements are approximate PLEASECONTACTOURSER...

Отзывы: