:CURSor:TRACk
Command List:
:CURSor:TRACk:AXValue?
Syntax
:CURSor:TRACk:AXValue?
Description
Queries the X value at Cursor A (X cursor) in the track mode of cursor measurement. The default unit is s.
Remarks
In the track mode, when Cursor A (Y cursor) is adjusted vertically, Cursor A (X cursor) will
automatically track the time or frequency of the waveform of the corresponding track source channel
at Cursor A (Y cursor).
For the horizontal position of Cursor A (X cursor), refer to the :CURSor:TRACk:CAX command.
Return Format
The query returns the X value in scientific notation.
:CURSor:TRACk:AXIS
Syntax
:CURSor:TRACk:AXIS <mode>
:CURSor:TRACk:AXIS?
Description
Sets or queries the track axis in the track mode of cursor measurement.
Parameter
Name
Type
Range
Default
<mode>
Discrete
X|Y
Y
Remarks
When X is selected as the track axis, you can use the :CURSor:TRACk:CAY and :CURSor:TRACk:CBY
commands to adjust the vertical position of Y cursor. Then, X cursor will automatically track the time or
frequency of the waveform of the corresponding measurement source at Y cursor. Besides, you can
also use the :CURSor:TRACk:SEQuence command to set the track type of X cursor.