GENERAL
19
Functioning phases (table 1)
Nr. displayed Ch
a
racteristic
00
Standby
01
Ignition prevented
02
Fan start
03
Pre-ventilation
04
Wait time
05
Pre-ignition time
06
Safety time, constant
07
Safety time, variable
10
Central heating mode
11
Domestic hot water mode
12
Simultaneous CH and DHW mode
20
Post-ventilation with last control used
21
Post-ventilation at pre-ventilation level
22
Home run (*)
99
Burner lockout (error code displayed)
(*) Home run = Boiler status after reset.
EXTENDED INFORMATION LEVEL 1: temperatures
Press the
I
key.
Press and hold both
D
U
keys for at least 3 seconds.
Press one of the
+
-
keys until you reach the required parameter.
Temperature
Nr.
Characteristic
b 0
Control board error code
b 1
Boiler return temperature
b 2
Not used
b 3
Flue gas temperature
b 4
Outdoor temperature
b 5
Compound outdoor temperature
b 6
Attenuated outdoor temperature
b 7
Not used
b 8
Reserved
b 9
Reserved