The boilers manufactured in our factories are checked even in the smallest details
in order to protect users and installers against possible injury. After working on
the product, qualified personnel must check the electrical wiring, in particular the
stripped part of leads, which must not protrude from the terminal board and avoiding
possible contact with live parts of the leads themselves.
b
This installer and user manual constitutes an integral part of the product: make sure
they are always kept with the appliance, even if it is transferred to another owner or
user, or moved to another heating system. In the event of loss or damage, please
contact your local Technical Assistance Centre for a new copy.
b
Boiler installation and any other assistance and maintenance operations must be
carried out by qualified personnel according to the pr
ovisions of the legislation in
force.
b
The installer must instruct the user about the operation of the appliance and about
essential safety regulations.
b
This boiler must only be used for the application it was designed for. The manufacturer
accepts no liability within or without the contract for any damage caused to people,
animals and property due to installation, adjustment and maintenance errors or to
improper use.
b
This appliance should not be operated by children younger than 8 years, people
with reduced physical, sensory or mental capacities, or inexperienced people
who are not familiar with the product, unless they are given close supervision or
instructions on how to use it safely and are made aware by a responsible person
of the dangers its use might entail. Children must not play with the appliance. It is
the user's responsibility to clean and maintain the appliance. Children should never
clean or maintain it unless they are given supervision.
b
After removing the packaging, make sure the content is in good condition and
complete. Otherwise, contact the dealer from whom you purchased the appliance.
b
The safety valve outlet must be connected to a suitable collection and venting
system. The manufacturer declines all liability for any damage caused due to any
intervention carried out in the safety valve.
b
The seal of the condensate drainage connection line must be secure, and the line
must be fully protected against the risk of freezing (e.g. by insulating it).
b
Check that the rainwater drainage channel of the flue gas exhaust coupling and the
relative connecting pipe are free of obstructions.
b
Dispose of all the packaging materials in the suitable containers at the corresponding
collection centres.
b
Dispose of waste by being careful not to harm human health and without employing
procedures or methods which may damage the environment.
At the end of its life, the product should be not be disposed of as solid urban waste,
but rather it should be handed over to a differentiated waste collection centre.
During installation, inform the user that:
b
In the event of water leaks, the water supply must be shut off and the Technical
Assistance Centre contacted immediately
b
Periodically check that the operating pressure of the hydraulic system is comprised
between 1 and 1.5 bar. Otherwise contact the Technical Assistance Service or
professionally qualified personnel.
If the boiler is not used for a long period of time, it is recommended to perform the following
operations:
b
Turn the main switch of the appliance and the main switch of the system to "off"
b
Close the fuel and water taps of the heating and domestic hot water system
b
Empty the heating and domestic hot water circuits if there is the risk of freezing
b
Boiler maintenance must be carried out at least once a year; this should be booked
in advance with the Technical Assistance Centre to ensure the necessary safety
standards.
b
For the assembly, programming and commissioning of the boiler when used in
hybrid systems with a heat pump, storage cylinder and solar heating circuit refer
to the system manual.
For safety reasons, please remember that:
a
Do not access the inside of the boiler. Any work on the boiler should be carried out
by the Technical Assistance Centre or by professionally qualified personnel.
a
It is forbidden to activate electric devices or appliances such as switches, household
appliances and so on if you notice a smell of fuel or unburnt fuel. In this case:
ventilate the room by opening the doors and windows:
-
close the fuel shut-off device;
-
ask the Technical Assistance Service or professionally qualified personnel to
intervene promptly.
a
It is forbidden to touch the appliance while barefoot or if parts of your body are wet.
EN
ENGLISH
a
Any technical or cleaning operation is forbidden before disconnecting the appliance
from the main power supply by turning the system's main switch to "OFF" and the
main switch of the boiler to "OFF".
a
Do not modify the safety or adjustment devices without the manufacturer’s
authorisation and precise instructions.
a
It is prohibited to pull, detach or twist the electrical cables coming from the appliance
even if it is disconnected from the mains power supply.
a
Avoid blocking or reducing the size of the air vent openings in the installation
room, do not leave inflammable containers and substances in the room where the
appliance is installed.
a
Do not leave flammable containers and substances in the room where the device
is installed.
a
It is forbidden to disperse the packaging material in the environment and leave it
within children's reach as it may be a potential source of danger. It must be disposed
in accordance with the present law.
a
It is forbidden to obstruct the condensate drain outlet. The condensate drain pipe
should be facing the discharge pipe, preventing the formation of further drain pipes.
a
Never carry out any work on the gas valve.
INSTALLATION MANUAL
2
DESCRIPTION
The
Family
boilers have a new ACC combustion control system (active combustion control).
This new control system, developed by
Riello
, in all circumstances provides functionality,
efficiency and low emissions. The ACC system uses an ionisation sensor immersed in
the burner flame, whose information allows the control board to operate the gas valve that
regulates the fuel. This sophisticated control system provides for the auto adjustment of
the combustion, thereby eliminating the need for an initial calibration The ACC system can
adapt the boiler to operate with different gas compositions, different pipe lengths and various
altitudes (within the design limits). The ACC system can also perform an auto-diagnostic
operation that locks out the burner before the permitted upper emission limit is exceeded.
Family
is a type C condensing wall-hung boiler to be used for heating and the production
of domestic hot water. Depending
on the fume discharge accessory used, it is classified
in categories B23P; B53P; C(10);
C13,C13x; C33,C33x; C43,C43x; C53,C53x; C83,C83x;
C93,C93x. In configuration B23P (when installed indoors), the appliance cannot be installed
in bedrooms, bathrooms, showers or where there are open fireplaces without a proper
air flow. The room where the boiler is installed must have proper ventilation. Detailed
requirements for the installation of the flue, the gas piping and for ventilating the room, can
be found in UNI 7129-7131.
In configuration C, the appliance can be installed in any type of room and there are no
limitations due to ventilation conditions or room volume.
3 INSTALLATION
3.1
Cleaning the system and characteristics of the water
In the case of a new installation or replacement of the boiler, it is necessary to clean the
heating system. To ensure the device works well, top up the additives and/or chemical
treatments (e.g. anti-freeze liquids, filming agents, etc.) and check the parameters in the
table are within the values indicated.
PARAMETERS
UM
HEATING CIRCUIT WATER
FILLING WATER
pH value
7–8
-
Hardness
°F
-
< 15
Appearance
-
clear
Fe
mg/kg
0.5
-
Cu
mg/kg
0.1
-
3.2
Receiving the product
The
Family
boiler is shipped in a single pack, protected by cardboard packaging.
The boiler is supplied as standard with the following material:
-
Instruction booklet for the installer/user/technical assistance service
-
Bar code labels
-
Pre-assembly template
-
Package with plumbing fittings
-
Bypass valve
-
Flat gasket
-
SRD device
-
Condensate drain pipe
-
Flexible hose safety valve
-
Electric connections box
b
The instruction booklets are an integral part of the boiler and there it is recommended
to read them carefully and keep them in a safe place.
3.3
Handling (Fig. 6)
After unpacking, handling of the boiler is done manually using the support frame.
3.4
Installation room
The
Family
boiler can be installed in various types of room, as long as the discharge of the
combustion product and the combustion air suction are outside the room itself. In this case
the room does not need any ventilation opening since the
Family
boilers have a combustion
circuit that is "airtight" with respect to the installation environment.