ENGLISH
29
9.2.1
ON
If
ON
is selected, the zone requests are met.
9.2.2
AUTO
If
AUTO
is selected, the zone requests will be managed based on a scheduled programme.
9.2.3
MANUAL
If
MANUAL
is selected, the zone requests will be managed based on the setpoint set by
the user.
9.2.4
HEAT OFF
If
HEAT OFF
is selected, the zone requests will not be fulfilled.
NOTE
: if you want to deactivate the zone in SUMMER or in WINTER, you must select the
pre-set season (SUMMER or WINTER in the BOILER menu) and set the zone concerned
to OFF.
10 SET
With the
SET
function it is possible to configure the
HEATING
,
HOT WATER
and
PREHEATING setpoints. To do this, it is necessary to highlight the desired entry using the
“
UP
” and “
DOWN
” keys and then pressing “
ENTER
” to confirm the selection.
Pressing “
BACK
” takes you back to the initial screen without making any selection.
HEATING
HOT WATER
PREHEATING
SET
10.1 Heating
Press the “
UP
” and “
DOWN
” keys to change the heating setpoint and confirm the selection
by pressing “
ENTER
”. Press “
BACK
” to return to the
SET
screen without making any
selection.
78,0
°C
HEATING
SET
When an outdoor temperature sensor is installed, the outlet temperature is automatically
selected by the system, which quickly adjusts the ambient temperature according to the
variations in the outdoor temperature. If you want to change the temperature, raising it or
lowering it with respect to that automatically calculated by the electronic board, it is possible
to change the HEATING setpoint selecting the desired comfort level within the range (-5 ÷
+5).
The user is then asked to confirm the setpoint setting: select
CONFIRM
or
CANCEL
using the “
UP
” and “
DOWN
” keys, and confirm the selection pressing “
ENTER
”.
Once the selection is confirmed, the display returns to the
SET
screen. If the selection is
cancelled or the “
BACK
” key is pressed you return to the previous
SET
screen.
CONFIRM OR DELETE SELECTION
CONFIRM
CANCEL
THE PARAMETER WILL BE
CHANGED
SET
10.2 Hot water
Press the “
UP
” and “
DOWN
” keys to change the boiler’s domestic hot water setpoint. Press
“
ENTER
” to confirm the selection.
Press “
BACK
” to return to the
SET
screen without making any selection.
58,0
°C
HOT WATER
SET
The user is then asked to confirm the setpoint setting: select
CONFIRM
or else
CANCEL
using the “
UP
” and “
DOWN
” keys and confirm the confirmation with “
ENTER
”.
Once the selection is confirmed, the display returns to the previous
SET
screen.
If the selection is cancelled or the “
BACK
” key is pressed you return to the
SET
screen.
CONFIRM OR DELETE SELECTION
CONFIRM
CANCEL
THE PARAMETER WILL BE
CHANGED
10.3 Preheating
This function keeps the water in the domestic hot water exchanger hot, to reduce standby
times when a request is made. When the preheating function is enabled, the symbol P
comes on with a steady light at the top of the domestic hot water icon. During burner ignition
following a preheating request, the symbol P starts flashing.
It is possible to access the PREHEATING function selecting
SET
on the main screen of
the REC10. Setting PREHEATING = 1 the boiler’s domestic hot water function activates.
To deactivate the preheating function, set the parameter to PREHEATING = 0, the symbol
P switches off. The function is not active when the boiler is OFF.
0
PREHEATING
CONFIRM OR DELETE SELECTION
CONFIRM
CANCEL
THE PARAMETER WILL BE
CHANGED
11 INFO
The
INFO
function can be used to display a series of data regarding the system.
ATTENTION
- The displayed data cannot be modified.
Press the “
UP
” and “
DOWN
” keys to go through the list of information available, in this order:
-
SCREED HEATER OPERATING HOURS
-
FLOW PROBE
-
RETURN PROBE
-
DOMESTIC HOT WATER PROBE
-
FLUE GAS PROBE
-
OUTDOOR TEMPERATURE SENSOR
-
EXT T FOR THERMOREG
-
FAN
-
ZONE 1 DELIVERY
-
ZONE 2 DELIVERY
-
FLUE GAS PROBE OP. HOURS
-
MAIN ZONE SET-POINT
-
ZONE 1 SET-POINT
-
ZONE 2 SET-POINT
-
SYSTEM PRESSURE.
The “
ENTER
” key is inactive.
The “
BACK
” key allows you to return to the initial screen.
In the absence of additional zones or if the screed heater function is not operating, the
relative information will not be displayed.
12 MENU
Using the MENU it is possible to access the configuration of the SETTINGS and the TIME
SCHEDULE (available only if the timer is enabled (POR=1).
To do this, it is necessary to highlight the desired entry using the “
UP
” and “
DOWN
” keys and
then pressing “
ENTER
” to confirm the selection.
Pressing “
BACK
” takes you back to the initial screen without making any selection.
TIME SCHEDULE
INSTALLATION
SELECT OPTION
MENU
12.1 Settings
Select this function to modify the following settings:
-
TIME&DATE
-
LANGUAGE
-
BACKLIGHT.
To access the desired setting, it is necessary to highlight it using the “
UP
” and “
DOWN
” keys
and then pressing “
ENTER
” to confirm the selection.
Press “