Access to the technical parameters
Through the REC10 it is possible to access, using the TECHNICAL menu, a series of
parameters that can be programmed to allow you to personalise the operation of the boiler:
-
select MENU on the main page of the REC10 and press "
ENTER
"
30
°C
.3
MENU
STATE
SET
INFO
AIR PURGING CYCLE
FRI
1.3
bar
18/05/2013
12:17
PLANT
-
keep the “
BACK
” and “
DOWN
” keys pressed at the same time to enter the password
menu (about 5 sec)
SETTINGS
SELECT OPTION
FRI
18/05/2013
12:17
MENU
-
with the “
U
P” and “
DOWN
” keys select the password to access the authorisation level
INSTALLER or SERVICE, depending on the level of the tree menu, then press “
ENTER
”
00
INSERT PASSWORD
-
select TECHNICAL with the "
UP
" and "
DOWN
" keys, confirming the selection with
"
ENTER
"
SELECT OPTION
SETTINGS
TECHNICAL
MENU
-
access the desired menu and change/view the parameter concerned (see "structure of
the MENU tree of the REC10").
It is possible to return to the start page at any time by keeping the
CANCE
L
key pressed
for at least 2 seconds.
5 COMMISSIONING
5.1
Preliminary checks
The first ignition should be carried out by expert personnel from an authorised Technical
Assistance Service Centre. Before starting up the boiler, check:
-
that the data of the supply networks (electricity, water, gas) correspond to the label data
-
that the extraction pipes of the flue gases and the air suction pipes are working correctly
-
that conditions for regular maintenance are guaranteed if the boiler is placed inside or
between items of furniture
-
the seal of the fuel adduction system
-
that the fuel flow rate corresponds to values required by the boiler
-
that the fuel supply system is sized to provide the correct flow rate to the boiler, and that
it has all the safety and control devices required by current regulations
-
that the circulator rotates freely because, especially after long periods of inactivity,
deposits and/or debris can prevent free rotation.
Eventual releasing of the circulator shaft
-
Insert a screwdriver in the hole (1) of the circulator.
-
Press (
a
) and turn the Phillips no. 2 screwdriver (
b
) until the motor shaft is released.
Perform this operation with extreme caution to avoid damaging the components.
a
b
1
5.2
Programming the boiler
-
Position the system’s master switch to the “on” position.
-
If necessary set the TIME and DATE setting the HOURS, MINUTES, DAY, MONTH and
YEAR with the “
UP
” and “
DOWN
” keys, confirming the selection.
ENTER TIME AND DATE
USE THE ARROWS TO MODIFY
12
17
18/11/2013
:
TIME & DATE
Note
:
it is possible to change the TIME and DATE settings, as well as the LANGUAGE
and the duration of the back-lighting, even afterwards by entering the MENU from the main
screen and then selecting SETTINGS.
b
Each time that the boiler is powered an automatic venting cycle is carried out lasting
4 min. To interrupt the vent cycle, carry out the procedure explained in the section
“Initial commissioning”.
-
Set the boiler to OFF
on the REC10 select the menu STATE and then BOILER.
42
°C
MENU
STATE
SET
INFO
HOT WATER TEMPERATURE
FRI
1.3
bar
18/05/2013
12:17
PLANT
BOILER
MAIN ZONE
STATE
OFF
HOT WATER ONLY
HEATING AND HOT WATER
BOILER
-
Through the REC10 it is possible to access, using the TECHNICAL menu, a series of
parameters that can be programmed to allow you to personalise the operation of the
boiler based on the type of system.
-
Then set the parameters according to the desired operating modes.