4.5 Attach the cable carrier
The cable carrier prevents that the roller-screen system causes damage to the power cable during
movement of the tube motor.
Do the procedure that follows.
1.
Use the pop-rivets (5) to attach the end connector (MCP) to the cable-carrier bracket (8).
2.
Make marks of the
position
of the cable-carrier mounting-bracket (7) on the post (B). This
position is equal to the
length l1 multiplied by 0.5 to 0.6
. Drill the holes for the applicable
screws (7.1) or bolts (7.1), into the post (B).
3.
Use the screws (7.1) or bolts (7.1) to install the cable-carrier mounting-bracket (7).
4.
Use the pop-rivets (5) to attach the end connector (FCP) to the cable-carrier mounting-bracket
(7).
4.5.1
MCP
0.5-0.6 x l1
l1
4.5.2
FCP
Ridder Drive Systems
T
+31 (0)341 416 854
F
+31 (0)341 416 611
I
www.ridder.com