7.2 Special tools and equipment
Adjusting switch RB50Eᵖˡᵘˢ tube motor
For the commissioning of an RB50Eᵖˡᵘˢ tube motor the “Adjusting switch RB50Eᵖˡᵘˢ” is necessary.
The adjusting switch (9) for the RB50Eᵖˡᵘˢ tube motor is only used:
•
To set the limit-switch system
•
Drive the tube motor during installation, maintenance or service.
Connect the tube motor, for the “operating mode”, always to the control box again.
Buttons of the adjusting switch:
•
9.1 Up-Down button
•
9.2 Programming button.
Connect the adjusting switch to the tube motor
Connect the wires from the tube motor “colour to colour” to the connection block on the adjusting
switch.
Note:
If the connection is incorrect it is
not
possible to
set
the tube motor (again).
7.3 RB50Eᵖˡᵘˢ limit-switch system
The RB50Eᵖˡᵘˢ tube motor has an electronic limit-switch system with a pulse counter.
The pulse counter makes sure that:
•
The tube motor stops at an end position
•
The tube motor stops (as a safety precaution) if there is an overload.
Make sure that there is no blockage of the system before the limit-
switch system of the RB50Eᵖˡᵘˢ is set.
This prevents damage or injury!
The adjusting switch is not applicable for continuous use. Use this
only during installation, commissioning, maintenance or service!
Do a test with the Up-Down button for the related directions-of-
rotation before the limit-switch system is set.
Refer to §7.4, step 4.